This paper presents a new partial discharge (PD) location technique for power cables. Unlike commonly used time-domain reflectometry (TDR) methods, this technique is based on the analysis of phase difference between the direct and reflected waves of a PD pulse measured at the cable end. The phase difference at various frequencies can be obtained from the cross Fourier spectral density function. After implementing a phase unwrapping algorithm, the defect is located. This technique has been tested using the Electromagnetic Transient Program (EMTP) on the model of a 20 kV, 1-km underground cable. The simulation takes into account the frequency-dependent parameters of the cable and the measurement accuracy of the A/D converter (8-bit). The signal-to-noise ratio (SNR) varies from 10 dB to -5 dB for all computer simulations. The statistical results are given to demonstrate the performance of the proposed technique.
机译:本文提出了一种新的电力电缆局部放电(PD)定位技术。与常用的时域反射法(TDR)方法不同,此技术基于对在电缆端测量的PD脉冲的直接波和反射波之间的相位差进行分析。可以从交叉傅立叶频谱密度函数获得各种频率下的相位差。在实施相位展开算法之后,找到缺陷。该技术已使用电磁暂态程序(EMTP)在20 kV,1公里地下电缆的模型上进行了测试。该仿真考虑了电缆的频率相关参数和A / D转换器(8位)的测量精度。对于所有计算机仿真,信噪比(SNR)从10 dB到-5 dB不等。统计结果表明了所提出技术的性能。