首页> 外文期刊>IEEE Transactions on Dielectrics and Electrical Insulation >Creeping discharge and flashover of solid dielectric in air at atmospheric pressure: experiment and modelling
【24h】

Creeping discharge and flashover of solid dielectric in air at atmospheric pressure: experiment and modelling

机译:大气中空气中固体电介质的蠕变放电和闪络:实验和建模

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper is aimed at the study of the propagation of discharge at the surface of solid insulator and the development of an analytical model of flashover in air. The experimental results show that the critical conditions of flashover are met when the discharge reaches the half of creeping distance. Using electrical equivalent circuit and the impedance criterion, we developed a relationship giving the flashover voltage (FOV). This formula evidences the fact that flashover voltage depends on the discharge temperature, the capacitance and the resistance of solid insulator, and the propagation conditions of the discharge. We also show that the computed FOV are in a good accordance with the experimental data.
机译:本文旨在研究固体绝缘子表面放电的传播以及建立空气中闪络分析模型。实验结果表明,当放电达到蠕变距离的一半时,就满足了闪络的临界条件。使用等效电路和阻抗标准,我们建立了给出闪络电压(FOV)的关系。该公式证明了闪络电压取决于放电温度,固体绝缘体的电容和电阻以及放电的传播条件这一事实。我们还表明,计算出的视场与实验数据非常吻合。