Understanding the ageing aspects of natural ester based insulation liquid in power transformer

机译:了解电力变压器中基于天然酯的绝缘液体的老化情况

获取原文
获取原文并翻译 | 示例
           

摘要

Cellulose based insulation materials and mineral oils have widely been used in liquid filled transformers. Environmental and fire-safety concerns have accelerated the use of Natural Esters (NE) as a sustainable alternative to mineral oil. There is a rapid growth of their application for distribution level transformers. To ensure a safe and long-term operation of the vegetable oil filled transformers, it is necessary to clarify the knowledge gaps with respect to the ageing of vegetable oil impregnated cellulose and insulation diagnostic methods. The condition monitoring of mineral oil filled transformers has been well characterised, due to the numerous laboratory and field studies conducted during the past several decades. The application of these available condition monitoring techniques for NE filled transformers is yet to be validated as the use of NE for power transformers is in the evaluation stage. In this paper the performance of NE as insulation in transformers by evaluating the ageing of NE impregnated cellulose pressboard is presented. For this purpose, an accelerated ageing experiment has been carried out in sealed tubes at 120 °C. The ageing of oil impregnated pressboard has been characterised by decrease in the degree of polymerisation (DP) of pressboard, and the formation of both 2-furfuraldehyde and dissolved carbon dioxide (CO) in the oil. The structural changes of cellulose have been supported by Fourier Transform Infrared (FTIR) spectra. Moreover, the results have been compared with cellulose insulation samples aged under similar conditions in conventional mineral oil. Acidity value, dissipation factor and viscosity measurements have been used to compare the stability of NE in a transformer operating environment to mineral oil.
机译:纤维素基绝缘材料和矿物油已广泛用于充液变压器中。对环境和消防安全的关注加速了天然酯(NE)作为矿物油的可持续替代品的使用。它们在配电级变压器中的应用正在迅速增长。为了确保植物油填充变压器的安全和长期运行,有必要澄清有关植物油浸渍纤维素的老化和绝缘诊断方法的知识差距。由于在过去的几十年中进行了大量的实验室和现场研究,矿物油填充变压器的状态监视已被很好地表征。这些可用的状态监测技术在NE变压器中的应用尚待验证,因为NE在电力变压器中的使用尚处于评估阶段。本文通过评估浸渍了NE的纤维素压制板的老化程度,介绍了NE在变压器中的绝缘性能。为此,已在密闭管中于120°C进行了加速老化试验。浸油的压榨板的老化的特征在于压榨板的聚合度(DP)降低,并且在油中形成了2-糠醛和溶解的二氧化碳(CO)。傅立叶变换红外(FTIR)光谱支持了纤维素的结构变化。此外,将结果与常规矿物油中在类似条件下老化的纤维素绝缘样品进行了比较。酸度值,耗散因数和粘度测量值已用于比较变压器运行环境中NE与矿物油的稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号