Medium voltage underground cables are widely used in urban area as distribution power lines due to their advantages over overhead cables. Underground cables may suffer from partial discharge because of insulation degradation after certain period of time. In this paper, an improved multi-end partial discharge location algorithm called segmented correlation trimmed mean algorithm is proposed. The algorithm uses segmented correlation technique and trimmed mean data filtering technique to enhance the accuracy of partial discharge location algorithm. The algorithm had been tested in MATLAB environment which consists white Gaussian noise. First, discrete wavelet transform is carried out to suppress noisy signals. Next, segmented correlation technique is applied to the de-noised segmented partial discharge signals. Segmented correlation technique has manipulates partial discharge signals by performing cross correlation process on segmented partial discharge signals in order to reduce memory usage and algorithm execution time. Lastly, trimmed mean data filtering technique is applied to the estimated partial discharge location values to estimate new partial discharge location value. Trimmed mean data filtering technique does statistical process control on estimated partial discharge location values in order to minimize the error of estimated partial discharge location. The segmented correlation trimmed mean algorithm had been compared with the existing multi-end correlation-based algorithm. The result shown that the segmented correlation trimmed mean algorithm has better accuracy than multi-end correlation-based algorithm.
机译:由于中压地下电缆优于架空电缆的优点,因此在城市地区广泛用作配电电源线。地下电缆由于一定时间后绝缘性能下降而可能会局部放电。提出了一种改进的多端局部放电定位算法,称为分段相关修整均值算法。该算法采用分段相关技术和均值修剪滤波技术,提高了局部放电定位算法的精度。该算法已在包含白高斯噪声的MATLAB环境中进行了测试。首先,进行离散小波变换以抑制噪声信号。接下来,将分段相关技术应用于经去噪的分段局部放电信号。分段相关技术通过对分段局部放电信号执行互相关处理来操纵局部放电信号,以减少存储器使用量和算法执行时间。最后,将修整平均数据滤波技术应用于估计的局部放电位置值,以估计新的局部放电位置值。修整平均数据滤波技术对估计的局部放电位置值进行统计过程控制,以使估计的局部放电位置的误差最小。将分段相关修整均值算法与现有的基于多端相关的算法进行了比较。结果表明,分段相关修整均值算法比基于多端相关的算法具有更好的精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号