Evaluation of hard and soft tissue changes around implant in partially edentulous patients: a aclinico-radiographic study

机译:植入物中植入物的硬质和软组织的评估在部分透明患者中的变化:AClinico-anaprokichich

获取原文
           

摘要

Introduction:implant supported prosthesis has become a viable treatment option for missing teeth. An important tool to detect early changes around implants is the standardized assessment of peri-implant hard and soft tissue parameters. The purpose of this prospective study was to clinically and radiographically assess the soft and hard tissues around implants.Methods:ten (10) patients with 13 implant supported prosthesis were included in the study. Clinical parameters plaque index (PI), gingival index (GI), modified sulcus bleeding index (mSBI), peri-implant Probing Depth (PD), gingival margin Level, width of keratinized mucosa (WKM) and implant mobility were measured at loading and at 3 and 6 months. The radiographic crestal bone loss and peri-apical implant radiolucencies were also evaluated at loading and at 3 and 6 months. Student paired t test and correlation and regression analysis was done to evaluate the effect of clinical variables over bone loss.Results:there was decrease in the site specific PI, GI, mSBI and peri-implant PD and an increase in the gingival recession from baseline to 6 months. The WKM remained stable throughout the study. Significant crestal bone loss was observed around implants more on the distal as compared to the mesial aspect. No mobility or peri-apical implant radiolucency was observed. Regression analysis of the confounding variables with bone loss showed no significant effect.Conclusion:the occlusal loading of implants after 6 months showed significant bone loss (1mm), which was within acceptable limits and the soft tissues around implants were in good health.Copyright: Nidhi Mehrotra et al.
机译:简介:植入物支持的假体已成为缺牙的可行的治疗选择。检测植入物的早期变化的重要工具是Peri-植入物硬度和软组织参数的标准化评估。该前瞻性研究的目的是临床上和放射线上的植入物周围的柔软和硬组织。方法:十(10)例患有13例植入物支持的假体均被研究。临床参数斑块指数(PI),牙龈指数(GI),改性硫磺出血指数(MSBI),在装载时测量角蛋白化粘膜(WKM)和植入物迁移率的牙龈探测深度(PD),牙龈缘水平,在3和6个月。还在负荷和3个月和3个月时评估射线照相骨骨损伤和Peri-appical植入物含油。学生配对T测试和相关性和回归分析是为了评估临床变量对骨质损失的影响。结果:该网站特异性PI,GI,MSBI和Peri-incommant PD减少,从基线增加了牙龈衰退的增加到6个月。在整个研究中,WKM保持稳定。与虚长方面相比,在远端植入物中观察到显着的嵴骨质损失。没有观察到迁移率或静脉植入物覆盖物。骨质损失的混杂变量的回归分析显示出没有显着效果。结论:6个月后植入物的咬合载荷显示出显着的骨质损失(1mm),其在可接受的限度内,植入物周围的软组织处于良好状态。版权所有:nidhi mehrotra等。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号