首页> 外文期刊>Journal of Veterinary Internal Medicine >Comparison of pulmonary deposition of nebulized 99mtechnetium‐diethylenetriamine‐pentaacetic acid through 3 inhalation devices in healthy dogs
【24h】

Comparison of pulmonary deposition of nebulized 99mtechnetium‐diethylenetriamine‐pentaacetic acid through 3 inhalation devices in healthy dogs

机译:雾化99Mtechnetium - 二亚乙基三胺 - 五乙酸肺沉积与健康犬3次吸入装置的肺部沉积

获取原文
           

摘要

Background Inhalation treatment frequently is used in dogs and cats with chronic respiratory disease. Little is known however about the performance of delivery devices and the distribution of aerosolized drugs in the lower airways. Objective To assess the performance of 3 delivery devices and the impact of variable durations of inhalation on the pulmonary and extrapulmonary deposition of nebulized 99m technetium‐diethylenetriamine‐pentaacetic acid ( 99m Tc‐DTPA). Animals Ten university‐owned healthy Beagle dogs. Methods Prospective crossover study. Dogs inhaled the radiopharmaceutical for 5 minutes either through the Aerodawg spacer with a custom‐made nose‐muzzle mask, the Aerochamber spacer with the same mask, or the Aerodawg spacer with its original nose mask. In addition, dogs inhaled for 1 and 3 minutes through the second device. Images were obtained by 2‐dimensional planar scintigraphy. Radiopharmaceutical uptake was calculated as an absolute value and as a fraction of the registered dose in the whole body. Results Mean (±SD) lung deposition for the 3 devices was 9.2% (±5.0), 11.4% (±4.9), and 9.3% (±4.6), respectively. Differences were not statistically significant. Uptake in pulmonary and extrapulmonary tissues was significantly lower after 1‐minute nebulization, but the mean pulmonary/extrapulmonary deposition ratio (0.38 ±?0.27) was significantly higher than after 5‐minute nebulization (0.16?±?0.1; P = .03). No significant differences were detected after 3‐ and 5‐minute nebulization. Conclusion and Clinical Importance The performance of a pediatric spacer with a custom‐made mask is comparable to that of a veterinary device. One‐minute nebulization provides lower pulmonary uptake but achieves a better pulmonary/extrapulmonary deposition ratio than does 5‐minute nebulization.
机译:背景吸入治疗经常用于患有慢性呼吸道疾病的狗和猫。然而,对于递送装置的性能以及较低气道中的雾化药物的分布很少。目的评估3个递送装置的性能和吸入的可变持续时间对雾化99M核苷酸二亚乙基三胺 - 五乙酸(99M TC-DTPA)的肺部和外侧沉积的影响。动物十大拥有的健康犬。方法预期交叉研究。狗通过Aerodafg Spacer用定制的鼻子袋掩模,具有相同面具的Aerochamber Spacer或具有其原始鼻子面膜的Aerodawg垫片的Aerochamber垫片吸入了5分钟。此外,狗通过第二装置吸入1和3分钟。通过二维平面闪烁图像获得图像。将放射性药物摄取作为绝对值计算,作为全身注册剂量的一部分。结果平均值(±SD)3器件的肺沉积分别为9.2%(±5.0),11.4%(±4.9)和9.3%(±4.6)。差异没有统计学意义。 1分钟内爆发后肺和外肺组织的摄取显着降低,但平均肺/外析沉积比(0.38±0.27)显着高于5分钟的雾化后(0.16≤≤0.1; p = .03) 。在雾化3-5分钟后没有检测到显着差异。结论及临床重要性与定制掩模的儿科间隔物的性能与兽医器件的性能相当。一分钟的雾化提供较低的肺摄取,但达到比5分钟的雾化更好的肺/肺沉积比。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号