Quality of electric current delivered to the magnets of a particle accelerator is essential for safety and reliability of its operation. Even small discrepancies strongly affect the properties of particle beams. One of the sources of the disturbances is the appearance of induced currents caused by the electromagnetic interactions between the elements of the machine. In this paper the calculations of induced currents in by-pass lines of a SIS100 particle accelerator are presented. In order to find the values of the currents the self-inductances and mutual inductances of the by-pass lines are found. Due to the complex geometry of the line, especially of Ω-shaped dilatations, the numerical approach was employed. The calculations show that the size of induced currents increases with the distance between the cables in an individual bus-bar. The maximum discrepancy of the magnetic field in a dipole magnet is found to be 7.7 μT. The decrease of distance between the cables allows one to obtain a discrepancy of 1.2 μT.
机译:输送到粒子加速器磁体的电流质量对于其操作的安全性和可靠性至关重要。即使小差异也强烈影响粒子束的性质。扰动的一个来源是由机器元件之间的电磁相互作用引起的诱导电流的外观。本文介绍了SIS100粒子加速器的逐行线路的诱导电流的计算。为了找到电流的值,找到了旁路线的自电感和互感。由于线的复杂几何形状,尤其是ω形膨胀,使用数值方法。计算表明,诱导电流的尺寸随着各个总线杆中的电缆之间的距离而增加。发现偶极磁铁中的磁场的最大差异为7.7μT。电缆之间的距离降低允许人们获得1.2μT的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号