...
首页> 外文期刊>Sports medicine - open >Test Re-test Reliability of Single and Multijoint Strength Properties in Female Australian Footballers
【24h】

Test Re-test Reliability of Single and Multijoint Strength Properties in Female Australian Footballers

机译:在女性澳大利亚足球运动员中测试重新测试可靠性

获取原文

摘要

Purpose To examine the test re-test reliability of isometric maximal voluntary contractions (MVC) of hip adduction (ADD ISO ), hip abduction (ABD ISO ), and multijoint leg extension (SQUAT ISO ) in sub-elite female Australian footballers. Methods Data were collected from 24 sub-elite female Australian footballers (age 22.6 ± 4.5 years; height 169.4 ± 5.5 cm; body mass 66.6 ± 8.0 kg; 4.5 ± 4.4 years sport-specific training; 2.5 ± 2.0 years unstructured resistance training) from the same club on two non-consecutive days. Participants performed three isometric MVCs of ADD ISO , ABD ISO , and SQUAT ISO . The SQUAT ISO was performed at 140° knee flexion with a vertical trunk position and ADD ISO and ABD ISO measures were performed in a supine position at 60° of knee flexion and 60° hip flexion. Reliability was assessed using paired t tests and the intraclass correlation coefficient (ICC) with 95% confidence intervals (CI), typical error (TE), and coefficient of variation (CV%) with 95% CI. Results SQUAT ISO peak force (ICC .95; CV% 4.1), ABD ISO for left, right, and sum (ICC .90–.92; CV% 5.0–5.7), and ADD ISO for left, right, and sum (ICC .86–.91; CV% 6.2–6.9) were deemed acceptably reliable based on predetermined criteria (ICC ≥ .8 and CV% ≤ 10). Conclusion SQUAT ISO , ABD ISO , and ADD ISO tests demonstrated acceptable reliability for the assessment of peak force in sub-elite female Australian footballers, suggesting these assessments are suitable for muscle strength testing and monitoring adaptations to training.
机译:目的,研究髋关节内收(添加ISO),髋关节绑架(ABD ISO),髋关节绑架(ABD ISO)和次级精英女性澳大利亚足球运动员中的髋关节绑架(ABD ISO)和多节腿部延伸(Squat ISO)的测试重新测试的测试可靠性。方法从24个精英女性澳大利亚足球运动员收集数据(22.6±4.5厘米;身体质量66.6±8.0公斤; 4.5±4.4岁的运动特定培训; 2.5±2.0年的非结构化抵抗训练)同一个俱乐部在两个非连续日内。参与者执行了三个等距MVC的添加ISO,ABD ISO和Squat ISO。 Squat ISO在140°膝关节屈曲,垂直行李箱位置,并在60°的膝关节和60°Hip屈曲的仰卧位进行ISO和ABD ISO测量。使用配对的T测试和具有95%置信区间(CI),典型误差(TE)和含有95%CI的变异系数(CV%)来评估可靠性的可靠性。结果Squat ISO峰值力(ICC .95; CV%4.1),ABD ISO为左,右和总和(ICC .90- .92; CV%5.0-5.7),并为左,右和总和添加ISO( ICC .86-.91; CV%6.2-6.9)认为基于预定标准可接受可靠(ICC≥.8和CV%≤10)。结论Squat ISO,ABD ISO,并添加ISO测试对次精英女性澳大利亚足球运动员评估的可接受可靠性,这表明这些评估适用于肌肉力量测试和监测培训的调整。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号