...
首页> 外文期刊>Analytical methods >Quantitative UPLC-MS/MS analysis of the gut microbial co-metabolites phenylacetylglutamine, 4-cresyl sulphate and hippurate in human urine: INTERMAP Study
【24h】

Quantitative UPLC-MS/MS analysis of the gut microbial co-metabolites phenylacetylglutamine, 4-cresyl sulphate and hippurate in human urine: INTERMAP Study

机译:测量UPLC-MS / MS分析肠道微生物共代谢苯乙酰氨基苯乙酰氨基,4-羰基硫酸盐和人类尿液中的血管 - 夹层研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The role of the gut microbiome in human health, and non-invasive measurement of gut dysbiosis are of increasing clinical interest. New high-throughput methods are required for the rapid measurement of gut microbial metabolites and to establish reference ranges in human populations. We used ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) -- positive and negative electrospray ionization modes, multiple reaction monitoring transitions -- to simultaneously measure three urinary metabolites (phenylacetylglutamine, 4-cresyl sulphate and hippurate) that are potential biomarkers of gut function, among multi-ethnic US men and women aged 40–59 from the INTERMAP epidemiologic study (n = 2000, two timed 24-hr urine collections/person). Metabolite concentrations were quantified via stable isotope labeled internal standards. The assay was linear in the ranges 1ng mL?1 (lower limit of quantification) to 1000ng mL?1 (phenylacetylglutamine and 4-cresyl sulfate) and 3ng mL?1 to 3000ng mL?1 (hippurate). These quantitative data provide new urinary reference ranges for population-based human samples: mean (standard deviation) 24-hr urinary excretion for phenylacetylglutamine was: 1283.0 (751.7) μmol/24-hr (men), 1145.9 (635.5) μmol/24-hr (women); for 4-cresyl sulphate, 1002.5 (737.1) μmol/24-hr (men), 1031.8 (687.9) μmol/24-hr (women); for hippurate, 6284.6 (4008.1) μmol/24-hr (men), 4793.0 (3293.3) μmol/24-hr (women). Metabolic profiling by UPLC-MS/MS in a large sample of free-living individuals has provided new data on urinary reference ranges for three urinary microbial co-metabolites, and demonstrates the applicability of this approach to epidemiological investigations...
机译:肠道微生物组在人类健康中的作用,肠道失育症的非侵入性测量增加了临床兴趣。肠道微生物代谢物的快速测量需要新的高通量方法,并在人口中建立参考范围。我们使用超级性能液相色谱串联质谱(UPLC-MS / MS) - 正和负电喷雾电离模式,多次反应监测过渡 - 同时测量三种尿代谢物(苯乙酰戊酰胺,4-烯基硫酸盐和海皮)肠道功能的潜在生物标志物,来自Intermap流行病学研究的多族裔美国男女和40-59岁的女性(n = 2000,两个时间24-hr尿液收集/人)。通过标记的内标通过稳定同位素定量代谢物浓度。测定在距离1ng mlα1(定量下限)至1000ng mlα1(苯基乙酰戊胺和4-冠氨酸)和3ng mlα1至3000ng mlβ1(水海藻)中的线性。这些定量数据为基于人群的人类样品提供新的尿尿参考范围:苯乙酰戊胺的平均值(标准偏差)24-HR尿排泄为:1283.0(751.7)μmol/ 24-hr(男性),1145.9(635.5)μmol/ 24-人力资源(妇女);对于4-羰基硫酸酯,1002.5(737.1)μmol/ 24-hr(男性),1031.8(687.9)μmol/ 24-hr(女性);对于海绵,6284.6(4008.1)μmol/ 24-hr(男性),4793.0(3293.3)μmol/ 24-hr(女性)。 UPLC-MS / MS在大型自由生活中的UPLC-MS / MS的代谢分析已经为三个尿的微生物共同代谢物的尿参考范围提供了新数据,并证明了这种方法对流行病学调查的适用性......

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号