首页> 外文期刊>Biology of sport / >Reverse lactate threshold test accurately predicts maximal lactate steady state and 5 km performance in running
【24h】

Reverse lactate threshold test accurately predicts maximal lactate steady state and 5 km performance in running

机译:反向乳酸阈值测试精确地预测最大的乳酸稳定状态和5公里的运行性能

获取原文
       

摘要

This study evaluated the accuracy of the reverse lactate threshold (RLT) and the onset of blood lactate accumulation (OBLA; 4 mmol·L -1 ) to determine the running speed at the maximal lactate steady state (MLSS) and 5 km running performance in a field test approach. Study 1: 16 participants performed an RLT test, and 2 or more constant-speed tests, lasting 30 minutes each, to determine running speed at the MLSS. Study 2: 23 participants performed an RLT test and a 5000 m all-out run as an indicator of performance. The RLT test consisted of an initial lactate-priming segment, in which running speed was increased stepwise up to ~5% above the estimated MLSS, followed by a reverse segment in which speed was decreased by 0.1 m·s -1 every 180 s. RLT was determined using the highest lactate equivalent ([La - ]/running speed) during the reverse segment. OBLA was determined during the priming segment and was set at a value of 4 mmol?L 1 . The mean difference in MLSS was 0.06 ± 0.05 m·s -1 for RLT, and 0.13 ± 0.23 m·s -1 for OBLA. OBLA showed a good concordance with the MLSS (ICC = 0.83), whereas RLT revealed excellent concordance with the MLSS with an ICC = 0.98. RLT showed a very high correlation with 5000 m speed (r = 0.97). The RLT exhibited exceptional agreement to MLSS and 5000 m running performance. Due to this high accuracy, especially concerning the small intraindividual differences, the RLT test may be superior to common threshold concepts. Further research is needed to evaluate its sensitivity during the training process.
机译:该研究评估了反向乳酸阈值(RLT)的准确性和血液乳酸积累(倾斜;4mmol·L-1)的开始,以确定最大乳酸稳态(MLS)和5公里的运行性能下的运行速度一个现场测试方法。研究1:16参与者进行了RLT测试,以及2个或更多恒定速度测试,持续30分钟,以确定MLSS的运行速度。研究2:23参与者进行了RLT测试,并以5000米的全输出作为性能指标。 RLT试验由初始乳酸灌注段组成,其中运行速度逐步增加至估计MLS上高于〜5%,其次是每180秒的速度减小0.1m·s -1的反向区段。在反向段期间使用最高乳酸等效物([La-] /运行速度)测定RLT。在引发段期间确定倾斜,并设定为4mmol?l 1的值。用于RLT的MLS的平均差异为0.06±0.05 m·s -1,倾斜为0.13±0.23 m·s -1。倾向于与MLSS(ICC = 0.83)表现出良好的一致性,而RLT揭示了具有ICC ​​= 0.98的MLSS的优异的一致性。 RLT显示出与5000米的速度非常高(R = 0.97)。 RLT对MLSS和5000米的运行性能表现出特殊协议。由于这种高精度,特别是关于小的内部差异小,RLT测试可能优于共同的阈值概念。需要进一步研究来评估培训过程中的敏感性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号