首页> 外文期刊>Saudi Journal of OphthalmologybElectronic resource >Evaluation of intraocular pressure change and anterior segment parameters after intravitreal bevacizumab injection – Cannula size matters
【24h】

Evaluation of intraocular pressure change and anterior segment parameters after intravitreal bevacizumab injection – Cannula size matters

机译:玻璃纤维素贝伐木液注射后的眼内压变化和前段参数的评价 - 套管尺寸

获取原文
           

摘要

PURPOSE: To determine the changes in intraocular pressure (IOP) and anterior chamber parameters following intravitreal bevacizumab injection with different sizes of cannulas.METHODS: This clinical trial was conducted with 70 eyes of 70 patients who received an intravitreal injection of bevacizumab with 26 G (Group 1) or 30 G (Group 2) needle. Preinjection and postinjection 30th-min IOP and pentacam measurements were obtained. Anterior chamber depth (ACD), anterior chamber volume (ACV), central corneal thickness (CCT), corneal volume (CV), and iridocorneal angle (ICA) measurements were evaluated in pentacam.RESULTS: Preinjection mean IOP values in Group 1 and 2 were 14.7 ± 3.29 mm Hg and 15.1 ± 2.87 mm Hg, respectively. Postinjection mean IOP in Group 1 was 16.8 ± 6.24 mm Hg and in Group 2 was 20.3 ± 3.66 mm Hg. Postinjection mean IOP values were significantly higher than preinjection values in both groups (Group 1 P < 0.005 and Group 2 P < 0.001). IOP change was significantly higher in Group 2 after injection (P < 0.05). In both groups, the change in IOP found to be more significant in phakic eyes than pseudophakic eyes (Group 1 P < 0.001, Group 2 P < 0.001). CCT and CV were significantly higher in both groups 30 min after the injection than preinjection (Group 1 and Group 2; P < 0.01). In Group 2 ACD, ACV and ICA values were significantly lower than preinjection values (P < 0.05).CONCLUSION: Needle bore size is an important parameter that influences anterior segment parameters and IOP change in the intravitreal injection. IOP rise and anterior segment changes are more prominent with a thinner cannula.
机译:目的:以不同尺寸的套管内注射术中的眼内压(IOP)和前腔参数的变化。方法:该临床试验用70只眼睛进行了70只患者,其中70名接受玻璃体内注射Bevacizumab(第1组或30克(第2组)针。预注调和发出30th-min IOP和五抗酸甘酸测量。在五鲸群中评估前室深度(ACD),前腔体积(ACV),中央角膜厚度(CCT),角膜体积(CV)和ILIDocorneal角度(ICA)测量。结果:第1组和2组中的预注调平均IOP值分别为14.7±3.29 mm Hg和15.1±2.87 mm Hg。第1组中的发布平均IOP为16.8±6.24 mm Hg,第2组为20.3±3.66mm Hg。 PostInump Explate平均IOP值显着高于两组中的预注射值(第1组P <0.005和第2组P <0.001)。注射后2组IOP变化显着高(P <0.05)。在两组中,IOP的变化发现在Phakic眼中比假眼眼更显着(第1组P <0.001,第2组P <0.001)。在注射后30分钟后,CCT和CV显着高于预注调(第1组和第2组; P <0.01)。在第2组ACD中,ACV和ICA值显着低于预注点值(P <0.05)。结论:针孔尺寸是影响前段参数和IOP变化在玻璃体内注射中的重要参数。 IOP上升和前部段变化与较薄的插管更加突出。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号