首页> 外文期刊>Journal of Clinical Microbiology >Performance of Fully Automated Antimicrobial Disk Diffusion Susceptibility Testing Using Copan WASP Colibri Coupled to the Radian In-Line Carousel and Expert System
【24h】

Performance of Fully Automated Antimicrobial Disk Diffusion Susceptibility Testing Using Copan WASP Colibri Coupled to the Radian In-Line Carousel and Expert System

机译:使用Copan WASP Colibri耦合到Radian在线转盘和专家系统的完全自动抗微生物盘扩散易感性测试的性能

获取原文
           

摘要

ABSTRACT The purpose of the present study was to assess the agreement at the categorical level between the Vitek 2 system and the Colibri coupled to the Radian under real routine laboratory conditions. The 675 nonduplicate clinical strains included in this study (249 Enterobacterales isolates, 198 Pseudomonas aeruginosa , 107 Staphylococcus aureus , 78 coagulase-negative staphylococci, 38 Enterococcus faecalis , and 5 Enterococcus faecium ) were isolated from nonconsecutive clinical samples referred to our laboratory between June and November 2020. In addition, 43 carbapenemase-producing Enterobacterales (CPE) formerly identified and stored in our laboratory were added to the panel, for a total of 718 strains. The overall categorical agreements between the two compared methods were 99.3% (4,350/4,380; 95% CI 99% to 99.5%); 98.6% (2,147/2,178; 95% CI 98.0% to 99.0%); 99.4% (1,839/1,850; 95% CI 98.9% to 99.7%); and 99.4% (342/344; 95% CI 97.9% to 99.8%) for Enterobacterales , P. aeruginosa , Staphylococcus spp., and Enterococcus spp., respectively. The most important cause of the very major errors encountered on the Vitek 2 for P. aeruginosa (62%, 13/21) was related to the presence of heteroresistant populations. Among the 43 CPE included in this study, one OXA-48-like, and one OXA-181-like were missed by the Vitek 2, even by rigorously applying the CPE screening cutoffs defined by EUCAST. The Colibri coupled to the Radian provide a fully automated solution for antimicrobial disk diffusion susceptibility testing with an accuracy that is equal to or better than that of the Vitek 2 system.
机译:摘要本研究的目的是评估Vitek 2系统之间的分类水平的协议和在真正的日常实验室条件下耦合到弧度的Colibri。本研究中包含的675个非卫生型临床菌株(249 excobacterales分离株,198个假单胞菌铜绿假单胞菌,107个葡萄球菌,78个凝血酶 - 阴性葡萄球菌,38肠球菌粪便和5个肠球菌饲料)与我们在6月和我们的实验室之间的非典型临床样本中分离出来2020年11月。此外,将以前鉴定并储存在我们实验室中的43种碳碱酶活性的肠杆菌(CPE)加入到面板中,总共718株。两种比较方法之间的整体分类协议为99.3%(4,350 / 4,380; 95%CI 99%至99.5%); 98.6%(2,147 / 2,178; 95%CI 98.0%至99.0%); 99.4%(1,839 / 1,850; 95%CI 98.9%至99.7%); 99.4%(342/344; 95%CI 97.9%至99.8%)用于肠杆菌,P.铜绿假单胞菌,葡萄球菌SPP。和肠球菌SPP分别。对于P.铜绿假单胞菌(62%,13/21)遇到的最重要的误差是遇到的非常重要的原因与杂氮群的存在有关。在本研究中包含的43个CPE中,Vitek 2也错过了一种Oxa-48状和一个牛肉-181,即使是严格地应用由eUcast定义的CPE筛选截止值。耦合到弧度的Colibri提供了一种全自动解决方案,用于抗微生物盘扩散易感性测试,其精度等于或优于Vitek 2系统的精度。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号