首页> 外文期刊>E3S Web of Conferences >Experimental results and analysis of throttling refrigeration with ternary mixed refrigerant
【24h】

Experimental results and analysis of throttling refrigeration with ternary mixed refrigerant

机译:三元混合制冷剂节流制冷试验结果及分析

获取原文
           

摘要

In-depth analysis of the influence of mixed working fluids on the thermodynamic performance of a throttling refrigeration cycle through experimental research. After optimizing the calculation of two ternary mixed working fluids with different compositions, the charging test is carried out, and the throttle characteristic curve of the mixed working fluid the law of temperature and pressure changes in the experiment was analyzed. The results show that: a mixed working fluid with a mixing ratio of 30.39mol% R14, 10.73mol% R170 and 58.87mol% R600A, at a pressure ratio of 2.5/0.1, a low temperature of -67.7°C is obtained, and the cooling time is 113.42min. The refrigeration system COP is 0.076; the mixing ratio is 30.39mol%R14, 15.73mol%R23 and 53.87mol%R600A mixed working fluid, in the case of a pressure ratio of 2.14/0.1, a low temperature of -76.4°C is obtained, and the cooling time is 160min, the refrigeration system COP is 0.106.
机译:深入分析混合工作流体对通过实验研究节流制冷循环热力学性能的深度分析。 在优化具有不同组合物的两个三元混合工作流体的计算之后,进行了充电测试,分析了混合工作流体的节流特性曲线,实验中的温度和压力变化的定律。 结果表明:在2.5 / 0.1的压力比下,具有30.39mol%R14,10.1.10.1,10.73mol%R170和58.87mol%R600A的混合工作流体,得到-67.7℃的低温, 冷却时间为113.42min。 制冷系统警察是0.076; 混合比率为30.39mol%R14,15.73mol%R23和53.87mol%R600A混合工作流体,在压力比为2.14 / 0.1的情况下,获得-76.4℃的低温,冷却时间是 160分钟,制冷系统警察是0.106。