首页> 外文期刊>The Egyptian Journal of Radiology and Nuclear Medicine >Can ultrasound suffice for triaging patients requiring surgical correction of rotator cuff tears-a comparative evaluation of ultrasound and magnetic resonance imaging
【24h】

Can ultrasound suffice for triaging patients requiring surgical correction of rotator cuff tears-a comparative evaluation of ultrasound and magnetic resonance imaging

机译:可以超声足以用于三环患者需要旋转箍撕裂的外科矫正 - 超声波和磁共振成像的比较评价

获取原文
           

摘要

Background:Objectives: To comparatively evaluate the role of ultrasound and MRI in rotator cuff and biceps tendon pathologies and to establish ultrasound as a consistently reproducible, quick and accurate primary investigation modality sufficient to triage patients requiring surgical correction of full thickness rotator cuff tears. Methods: Fifty patients, clinically suspected to have rotator cuff and/or biceps tendon pathologies, with no contraindications to MRI, were evaluated by US and MRI, in a prospective cross-sectional observational study. US was done with high-frequency linear probe, and MRI was done on a 1.5-T scanner using T1 oblique sagittal, proton density (PD)/T2 fat-suppressed (FS) oblique sagittal, T1 axial, PD/T2 FS axial, T1 oblique coronal, T2 oblique coronal and PD FS oblique coronal sequences. Statistical testing was conducted with the statistical package for the social science system version SPSS 17.0. The sensitivity, specificity, PPV, NPV and accuracy were also calculated to analyze the diagnostic accuracy of US findings correlating with MRI findings. A p value less than 0.05 was taken to indicate a significant difference.ResultsMean age was 45 years; 74% patients were males; 77% females and 60% males had tears. Majority of patients with rotator cuff tears were in the sixth decade of life. The frequency of tears was higher among older patients. Fourteen percent of patients had full thickness tears while 64% had partial thickness tears. US was comparable to MRI for detection of full thickness tears with overall sensitivity, specificity, PPV and accuracy of 93.8%, 100%, 100% and 98.2%, respectively (p value < 0.001). For partial thickness tears, US had overall sensitivity, specificity, PPV and accuracy of 75.6%, 82.6%, 89.5% and 78%, respectively (p value < 0.001), as compared to MRI. Subacromial-subdeltoid bursal effusion and long head of biceps tendon sheath effusion were common associated, though, non-specific findings.ConclusionUltrasound findings in our study were found to be in significant correlation with findings on MRI in detection of rotator cuff tears. US was equivalent to MRI in detection of full thickness tears and fairly accurate for partial thickness tears. Therefore, US should be considered as the first line of investigation for rotator cuff pathologies.
机译:背景:目标:相对评价超声波和MRI在旋转箍和二头肌肌腱病理中的作用,并将超声描绘成始终可再现,快速准确的主要调查模态,足以进行外科校正的分类患者全厚旋转器袖口撕裂。 方法:五十名患者,临床怀疑有旋转袖口和/或二头肌肌腱病理,通过美国和MRI评估MRI的禁忌症,在预期的横截面观察研究中。我们通过高频线性探头完成,使用T1斜矢状,质子密度(PD)/ T2脂肪压制(FS)斜矢状,T1轴向,PD / T2 FS轴向,在1.5-T扫描仪上完成MRI。 T1倾斜冠状,T2斜冠和PD FS斜冠状序列。统计检测与社会科学系统版本SPSS 17.0的统计包进行。还计算了敏感性,特异性,PPV,NPV和准确性,以分析与MRI调查结果相关的美国发现的诊断准确性。对于少于0.05的值,表明差异显着差异。培训级年龄为45岁; 74%的患者是男性; 77%的女性和60%的男性有泪水。大多数旋转袖口泪水的患者都在生命的第六十年中。老年患者的眼泪频率较高。 14%的患者具有全厚度的泪液,而64%具有部分厚度的泪液。我们与MRI相当,用于检测全厚度撕裂的全面敏感性,特异性,PPV和精度为93.8%,100%,100%和98.2%( P 值<0.001)。对于MRI相比,对于部分厚度撕裂,美国的总敏感性,特异性,PPV和精度分别为75.6%,82.6%,89.5%和78%,而<0.001)。亚脉络细胞泡沫突出积液和长头的二头肌肌腱鞘积液是常见的,但不具体的发现。在我们的研究中结论ulusualltravasound发现与MRI的检测中的研究结果显着相关。我们相当于检测全厚度撕裂的MRI,并相当准确地用于部分厚度撕裂。因此,美国应该被视为转子袖带病理的第一线。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号