首页> 外文期刊>Journal of Veterinary Internal Medicine >Three‐dimensional bladder ultrasound for estimation of urine volume in dogs compared with traditional 2‐dimensional ultrasound methods
【24h】

Three‐dimensional bladder ultrasound for estimation of urine volume in dogs compared with traditional 2‐dimensional ultrasound methods

机译:与传统的二维超声方法相比,三维膀胱超声估计尿液中尿量

获取原文

摘要

Background Although point‐of‐care volumetric assessments of the urinary bladder are not routinely performed in dogs, urine volume quantification can provide important clinical information including noninvasive urine output estimation. Hypothesis/Objective Use of 3‐dimensional (3D) ultrasound for determination of urinary bladder volume (UBV) in dogs will be accurate for different bladder volumes and will decrease the need for operator skill in measuring UBV compared to 2‐dimensional (2D) ultrasound evaluation. Animals Ten laboratory‐bred Beagle dogs. Methods Prospective, experimental study. Urinary bladders were infused with a calculated amount of sterile saline to represent small, medium, and large volumes. Each UBV was estimated and calculated by a board‐certified veterinary radiologist using 3 different 2D ultrasound formulas followed by use of a 3D ultrasound device by a novice. Measured UBVs were compared to the instilled UBV for both 2D and 3D ultrasound methods. Time from start to end of examination was recorded for both ultrasound methods in a subset of dogs. Results The 3D ultrasound device underestimated UBV with a mean difference of ?9.8 mL compared with 2D ultrasound that overestimated UBV with a difference of 4.2 to 20.3 mL dependent on the 2D formula used. The 3D ultrasound method took less time to measure UBV (mean of 80?seconds per measurement) compared to the 2D method (165?seconds per measurement; P = .02). Conclusions and Clinical Importance The tested 3D ultrasound device was found to be an accurate and rapid point‐of‐care tool for measuring UBV in dogs, providing a noninvasive method to estimate bladder volume in real time.
机译:背景技术虽然尿膀胱的护理点体积评估不是在狗的常规进行的,但尿量量化可以提供重要的临床信息,包括非侵入性尿量估计。假设/客观使用三维(3D)超声测定尿液中的膀胱体积(UBV)的侵略性将准确地对不同的膀胱卷进行准确,并且将降低与二维(2D)超声相比测量UBV的操作员技能的需求评估。动物十只实验室繁殖的小猎犬犬。方法预期,实验研究。尿膀胱用计算量的无菌盐水注入,以代表小,中等和大容量。每个UBV都是通过使用3种不同的2D超声公式的板认证的兽医放射学家估计和计算,然后通过新手使用3D超声装置。将测量的UBV与2D和3D超声方法的灌注UBV进行比较。从狗的子集中的超声方法记录了从开始到检查结束的时间。结果3D超声装置低估UBV,与2D超声相比,α.9.8ml的平均差异,其估计UBV的差异为4.2至20.3ml依赖于所用的2D公式。与2D方法相比,3D超声方法测量UBV的时间少时间来测量UBV(每次测量值为80Ω秒)(每次测量165秒; P = .02)。结论和临床重要性测试的3D超声装置是一种准确且快速快速的护理能力工具,用于测量狗的UBV,提供一种实时估计膀胱体积的非侵略性方法。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号