首页> 外文期刊>Journal of Korean medical science. >Development of a Smartphone-Based Digits-in-Noise Test in Korean: a Hearing Screening Tool for Speech Perception in Noise
【24h】

Development of a Smartphone-Based Digits-in-Noise Test in Korean: a Hearing Screening Tool for Speech Perception in Noise

机译:韩国智能手机基数的基于噪音测试的开发:噪声中言语感知的听力筛选工具

获取原文
           

摘要

BACKGROUND:The digits-in-noise (DiN) test is a speech-in-noise test to measure speech recognition threshold in noise adaptively. Herein, we aimed to develop the Korean version of the DiN test to provide a useful hearing screening tool for clinical as well as research purposes.METHOD:Spoken monosyllabic digits from 0 to 9 were recorded by a female speaker. The test list was constructed such that each digit was placed in three different positions. An optimization procedure was conducted to equate the audibility of each digit. After the optimization, the smartphone application for the Korean DiN (K-DiN) test was developed. For the adaptive measurement procedure, 180 new DiN triplets separated into six lists of 30 were created. Mean speech recognition threshold values for each list and session were measured to examine the test-retest and training effects of the test materials. In addition, speech recognition threshold values measured by different devices were compared to determine whether the speech recognition threshold levels differed.RESULTS:Optimization results showed that the mean speech recognition threshold and slope were ?11.55 dB signal-to-noise ratio and 10.21%/dB, respectively, which are comparable to levels shown in different-language versions of the DiN test. The results of the test-retest and training effects revealed no significant differences among the test sessions and lists. Additionally, the mean speech recognition threshold values measured by four different devices were not different, indicating the reliability of the test materials.CONCLUSION:We believe this study is the first to attempt to develop a K-DiN test. Our results indicate that this test can be used as a potentially reliable hearing screening tool.? 2020 The Korean Academy of Medical Sciences.
机译:背景:数字 - 噪声(DIN)测试是对语音测试,以便自适应地测量噪声中的语音识别阈值。在此,我们旨在开发韩国版的DIN测试,为临床以及研究目的提供有用的听力筛查工具。方法:由扬声器记录0到9的口头单音琴数字。测试列表构造成使得每个数字被放置在三个不同的位置。进行优化过程以等同于每个数字的可听性。优化后,开发了韩国DIN(K-DIN)测试的智能手机应用。对于自适应测量程序,创建了180个新的DIN三态分为六个列表30。测量每个列表和会话的平均语音识别阈值,以检查测试材料的测试保持和培训效果。另外,比较由不同设备测量的语音识别阈值以确定语音识别阈值水平是否有所不同。结果:优化结果表明,平均语音识别阈值和斜率是?11.55dB信噪比和10.21%/分别与DIN测试中的不同语言版本中所示的水平相当。测试重新测试和培训效果的结果显示测试会话和清单之间没有显着差异。另外,由四种不同器件测量的平均语音识别阈值并不不同,表明测试材料的可靠性。结论:我们认为这项研究是第一个尝试开发K-DIN测试的研究。我们的结果表明,该测试可用作潜在可靠的听力筛选工具。 2020韩国医学科学院。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号