首页> 外文期刊>Journal of control, automation and electrical systems >Impedance-Based Fault Location Algorithm for Double-Circuit Transmission Lines Using Single-End Data
【24h】

Impedance-Based Fault Location Algorithm for Double-Circuit Transmission Lines Using Single-End Data

机译:基于阻抗的双电路传输线路使用单端数据的故障定位算法

获取原文
获取外文期刊封面目录资料

摘要

Locating a fault in double-circuit transmission lines is a challenging task due to the mutual coupling effects between adjacent circuits of the line. Also, performance of impedance-based fault location schemes for double-circuit lines is adversely affected by fault resistance. Accurate fault location in double-circuit lines can be achieved if fault location schemes utilize reliable communication links. However, the communication links are not available or enabled in all transmission lines. To overcome such difficulty in fault location in double-circuit lines, a new fault location scheme is proposed for double-circuit transmission lines by using voltages and currents data extracted from single-end of the line. Only the negative-sequence current and voltage phasors during the fault are processed for calculating the fault location. The proposed fault location formula is derived by applying the Kirchhoff s voltage law around the parallel circuits and shunt capacitances loops. Obtained formula is applicable for all types of unbalanced faults and accordingly classification of fault types and phase selection are not required. The proposed scheme is immune to the fault resistance and insensitive to mutual coupling effects. Evaluation results verify that the accuracy of the proposed algorithm is very high under various fault resistances, fault locations, and fault types.
机译:由于线路相邻电路之间的相互耦合效应,定位双电路传输线中的故障是一个具有挑战性的任务。此外,对双电路管线的阻抗的故障定位方案的性能受到故障电阻的不利影响。如果故障定位方案利用可靠的通信链路,则可以实现双电路线中的精确故障位置。但是,通信链路不可用或在所有传输线中启用。为了克服双电路线中的故障位置的这种困难,通过使用从线的单端提取的电压和电流数据来提出用于双电路传输线的新故障定位方案。仅处理故障期间的负序电流和电压相量,以计算故障位置。通过在并联电路周围应用Kirchhoff S电压律并分流电容环来得出所提出的故障定位公式。获得的公式适用于所有类型的不平衡故障,因此不需要对故障类型和相位选择的分类。所提出的方案对防尘性的影响和对相互偶联效应的不敏感。评估结果验证,在各种故障电阻,故障位置和故障类型下,所提出的算法的准确性非常高。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号