首页> 外文期刊>Journal of applied clinical medical physics / >Effect of contrast dose on diagnostic performance in DCE‐MR breast imaging
【24h】

Effect of contrast dose on diagnostic performance in DCE‐MR breast imaging

机译:对比剂量对DCE-MR乳房成像诊断性能的影响

获取原文
       

摘要

Objective To assess the diagnostic performance of breast magnetic resonance (MR) imaging as a function of gadolinium contrast dose using a retrospective reader study. Material and Methods IRB approval was obtained prior to the start of this study and was HIPAA compliant. One‐hundred and fifty MR breast examinations were included that were acquired between January 2001 and December 2006. Seventy‐five patients received contrast doses (gadopentetate dimeglumine) by weight of 0.10?mmol/kg and 75 patients were imaged using fixed volumes of 20?ml. The images were assessed by two radiologists with performance calculated for each reader as well as a combined assessment. Dose response was measured by comparing performance between cases binned by dose: 0.10; and 0.13?mmol/kg. Statistical significance was calculated using a one‐sided Z ‐test for differences in proportions with interobserver agreement calculated using Cohen's kappa statistics. Results In the combined reader assessment with equivocal lesions classified as negative, sensitivity rose from 66% (19/29) to 92% (24/26, P ?0.01) and 95% (18/19, P ?0.01) with the specificity also increasing from 65% (32/49) to 87% (40/46, P ?0.01) and 86% (32/37, P =?0.01) corresponding to doses 0.10, 0.13?mmol/kg. With equivocal lesions classified as positive, sensitivity rose from 79% (23/29) to 92% (24/26, P ?0.10) and 95% (18/19, P ?0.10) Specificity also increased from 53% (26/49) to 72% (33/46, P ?0.05) and 70% (26/37, P =?0.05) with increasing dose. Interobserver agreement also improved at the higher doses.
机译:目的评估乳腺磁共振(MR)成像的诊断性能,作为使用回顾性阅读器研究的钆对比剂量的函数。材料和方法在本研究开始之前获得IRB批准,并符合HIPAA。包括2001年1月至2006年12月在2001年1月至12月期间收购的一百五十六年乳房检查。使用固定体积的20℃,七十五名患者接受对比剂量(钆丁酯二聚体)重量的重量为0.10≤mmol/ kg和75名患者。 ml。通过两个放射科医生评估图像,该辐射学家具有针对每个读者计算的性能以及组合评估。通过比较剂量的病例之间的性能来测量剂量反应:0.10;和> 0.13?mmol / kg。使用单侧Z-TSEST计算统计学意义,用于使用Cohen的Kappa统计计算的Interobserver协议的比例差异。结果较合并的读者评估,归类为阴性病变,敏感性从66%(19/29)上升至92%(24/26,P <0.01)和95%(18/19,P <0.01)特异性也从65%(32/49)增加到87%(40/46,p <β01)和86%(32/37,p = 0.01),对应于剂量0.10,>0.13Ω·莫醇/ kg。归类为阳性病变,敏感性从79%(23/29)升至92%(24/26,P <0.10)和95%(18/19,P <0.10)特异性也增加了53%( 26/49)随着剂量增加,26/49)至72%(33/46,p <Δ05)和70%(26/37,p = 0.05)。 Interobserver协议也以较高剂量改善。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号