The National Metrology Institute of Colombia (INM) uses high accuracy calibrators (such as Fluke 5720A/5730A) as AC current reference standards. We describe the implementation at INM of AC-DC current transfer standards by single junction thermal converters (SJTC) to improve the accuracy of AC measurements and give traceability to the International System of Units (SI) within the country. We describe the measurement model, present the uncertainty budget estimation accordingly to the Guide to the Expression of Uncertainty in Measurement (GUM) and analyze the effect of temperature and electrostatic on measurements. Expanded uncertainties between 68 繕A/A and 2.6 mA/A were obtained for the calibration of high accuracy calibrators and transconductance amplifiers for currents from 5 mA to 20 A (40 Hz to 5 kHz). The obtained measurement results are compatible with calibration results from the National Metrology Institutes like Centro Nacional de Metrolog穩a from Mexico (CENAM) and Accredited International Laboratories like Fluke.
机译:哥伦比亚国家计量研究所(INM)使用高精度校准器(如Fluke 5720A / 5730A)作为AC电流参考标准。我们通过单结热转换器(SJTC)描述了ACM电流转移标准INM的实施,提高了AC测量的准确性,并为该国内的国际单位系统(SI)提供可追溯性。我们描述了测量模型,将不确定性预算估计估计相应地向测量(胶)中不确定性表达的指南,分析了温度和静电对测量的影响。获得68‰/ a和2.6 mA / a之间的扩展不确定性,用于校准高精度校准器和跨导放大器,从5 mA到20 a(40 Hz至5 kHz)。获得的测量结果与来自墨西哥(CENAM)的Centro Nacional de Metrolog稳a等国家计量机构的校准结果兼容,如侥幸等认可的国际实验室。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号