首页> 外文期刊>World Allergy Organization Journal >Standardization of a colorimetric technique for determination of enzymatic activity of diamine oxidase (DAO) and its application in patients with clinical diagnosis of histamine intolerance
【24h】

Standardization of a colorimetric technique for determination of enzymatic activity of diamine oxidase (DAO) and its application in patients with clinical diagnosis of histamine intolerance

机译:二胺氧化酶(DAO)酶活性测定比色技术的标准化及其在组胺不耐受临床诊断患者中的应用

获取原文
           

摘要

Background Diamine Oxidase (DAO) has an essential role for degradation of exogenous histamine in the intestine; thus, histamine intolerance (HI) mainly has been correlated to a low concentration and/or activity of this enzyme. The objective of the study was to standardize a colorimetric technique to measure the enzymatic activity (function) of hDAO to then apply it to a series of 22 patients with a clinical diagnosis of HI. Methods For the standardization variables such as volume and type of sample, incubation time, wavelength of maximum absorption, types of substrates, and concentration of oxidized ascorbate were evaluated. Then the activity and concentration of DAO was determined in 22 patients diagnosed with HI and 22 healthy subjects. Results The mean of serum DAO concentration in the 22 patients was of 9.268?±?1.124 U/mL. The mean of serum DAO concentration in the 22 controls was of 20.710?±?2.509 U/mL, being significantly higher (P value 0.0002) the mean of the samples. The mean of serum DAO activity of the patients was of 1.143?±?0.085 U/L and the controls was 1.533?±?0.119 U/L, significantly greater than the patients (P value 0.011). In addition, the sensitivity of both techniques was 0.63. In the measuring of DAO concentration the specificity was 0.9, constituting a good diagnostic test, especially to rule out the true negatives. The determination of DAO activity had a specificity of 0.68. Conclusions Although we used a small number of patients and controls and the absorbance values were lower than expected, statistically significant differences were found in the levels of concentration and DAO activity between the patients with histamine intolerance and the controls. Therefore, the measuring of DAO concentration and DAO activity is a good diagnostic strategy for study suspect cases of HI. The simultaneous use of both assays allows to reduce positive and negative false results, for example, patients with normal DAO levels that could present a dysfunction in the activity of this enzyme.
机译:背景技术二胺氧化酶(DAO)具有在肠道中的外源组胺降解的重要作用;因此,组胺不耐受(HI)主要与该酶的低浓度和/或活性相关。该研究的目的是标准化色度技术,以测量HDAO的酶活性(功能),然后将其施加至一系列22名患者临床诊断。评价标准化变量的方法,例如样品的体积和类型,孵育时间,最大吸收波长,基质的类型,以及氧化抗坏血酸的浓度。然后在22例患有HI和22名健康受试者的患者中测定DAO的活性和浓度。结果22例患者血清DAO浓度的平均值为9.268?±1.124 U / ml。 22中的血清DAO浓度的平均值为20.710?±2.5​​09u / ml,显着升高(p值0.0002)样品的平均值。患者的血清DAO活性的平均值为1.143?±0.085 U / L和对照为1.533?±0.119 U / L,明显大于患者(P值0.011)。此外,两种技术的敏感性为0.63。在DAO浓度的测量中,特异性为0.9,构成良好的诊断测试,特别是排除真正的否定。 DAO活性的测定具有0.68的特异性。结论虽然我们使用了少数患者和对照,并且吸光度值低于预期,但在组胺不耐受和对照组患者之间的浓度和DAO活动水平中发现了统计学上显着的差异。因此,DAO浓度和DAO活性的测量是研究HI的疑虑病例的良好诊断策略。同时使用两种测定允许降低阳性和阴性假结果,例如患有正常DAO水平的患者,其可能在该酶的活性中存在功能障碍。

著录项