首页> 外文期刊>Orthopaedic surgery >Medial Metaphyseal Beak Angle as a Predictor for Langenski?ld Stage II of Blount's Disease
【24h】

Medial Metaphyseal Beak Angle as a Predictor for Langenski?ld Stage II of Blount's Disease

机译:内侧变形喙角度作为Langenski的预测因素?Blount病的LD阶段II

获取原文
           

摘要

Objective To determine the medial metaphyseal beak (MMB) cut‐off angle predicting Langenski?ld stage II of Blount's disease and to study the intra‐observer and inter‐observer reliabilities of angle measurements and the influence of the experience level of observers. Methods A retrospective study was conducted on children aged 2–4?years from January 2000 to December 2017. Children were identified through a computer‐based search. Children with Langenski?ld stage II of Blount's disease who had been initially evaluated at our institution were categorized into Blount group and children who were diagnosed with physiologic bowing were categorized into control group. Data on the patients' ages, genders, and affected sides were collected. The MMB angles were measured on standing anteroposterior radiographs of the knees. The angle was formed between one line drawn parallel to the medial cortex of the proximal tibia, and a second line running from the intersection of the first line with the proximal tibial metaphysis through to the most distal point of the MMB. Measurements were independently performed by six observers. All observers repeated the measurements 2?weeks after they were first done. Results There were 148 legs from 79 children (48 males and 31 females) with an average age of 28.6?months. The average MMB angle of the Blount group was 128.52°?±?5.38° ( P ‐value 122° (sensitivity 92.7%; specificity 97.0%) was associated with Langenski?ld stage II. The intraclass correlation coefficient of the intra‐observer reliability ranged from 0.93–0.97, and the inter‐observer reliability was 0.93. Conclusions By using anteroposterior (AP) radiographs of the knee, the MMB angle is a potential radiographic parameter to distinguish between Langenski?ld stage II of Blount's disease and physiologic bowed legs, with an MMB angle 122° predicting Langenski?ld stage II.
机译:目的判断朗安氏疾病的内侧复杂喙(MMB)截止角度预测Langenski阶段II,研究了观察者内部的角度测量和观察者的影响和观察者体验水平的影响。方法对2-4岁的儿童进行回顾性研究,从2000年1月到2017年12月。通过基于计算机的搜索来确定儿童。 Langenski的孩子们是最初在我们机构评估的Blount疾病的LD阶段II被分类为Blount组,并且被诊断出患有生理学弯曲的儿童被分类为对照组。收集了患者年龄,性别和受影响方面的数据。在膝盖的驻守前后射线照片上测量MMB角度。在一个平行于近侧胫骨的内侧皮质的一条线之间形成角度,以及从第一线的交叉点运行的第二线与近侧胫骨结合到MMB的最远端点。测量由六个观察者独立执行。所有观察者都重复测量2?他们首次完成后的时间。结果79名儿童(48名男性和31名女性)有148条腿,平均年龄为28.6岁?月。 BLOUNT组的平均MMB角度为128.52°θαα≤5.38°(P-value 122°(灵敏度92.7%;特异性97.0%)与LANGENSKIΔLD阶段II相关。观察者内部的腹部相关系数范围从0.93-0.97,观察者间可靠性为0.93。结论通过使用膝关节的前后(AP)X光片,MMB角度是区分Langenski的潜在射线照相参数,以区分Blount的疾病和生理弓形腿,具有MMB角度> 122°预测Langenski?LD阶段II。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号