首页> 外文期刊>Nuclear engineering and technology >Heat transfer characteristics of redan structure in large-scale test facility STELLA-2
【24h】

Heat transfer characteristics of redan structure in large-scale test facility STELLA-2

机译:大型试验设施史拉2中卫星结构的传热特性

获取原文
           

摘要

The construction of STELLA-2 facility is on-going to demonstrate the safety system of PGSFR and to provide comprehensive understanding of transient behavior under DBEs. Considering that most events are single-phase natural circulation flow with slow transient, STELLA-2 was designed with reduced-height of 1/5 length scale. The ratio of volume to surface area in the vessel can relatively increase resulting in excessive heat transfer. Therefore, a steady-state thermal-hydraulic analysis was performed and the effect of design change to reduce the heat transfer through redan was investigated. The heat transfer through single wall redan in STELLA-2 was 3% of the core power, comparable to 1% of the core power in PGSFR. By applying the insulated redan, about 70% of decrease effect was observed. The effect on transient behavior was also evaluated. The conclusion of this study was directly applied to the STELLA-2 design and the modified version is under construction.
机译:Stella-2设施的构建正在展示PGSFR的安全系统,并为DBES下提供综合了解瞬态行为。考虑到大多数事件是单相自然循环流量,斯特拉-2设计成1/5长度的减小高度。容器中的体积与表面积的比率可以相对增加,导致传热过多。因此,研究了稳态热液压分析,研究了设计变化以减少雷南传热的影响。通过单壁雷南在斯特拉-2中的热传递为核心功率的3%,可比PGSFR中的核心功率的1%相当。通过施加绝缘雷南,观察到约70%的减少效果。还评估了对瞬态行为的影响。本研究的结论直接应用于斯特拉-2设计,修改版正在建设中。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号