...
首页> 外文期刊>Motriz: Revista de Educao Física >The validity of Keiser-M3 stationary bicycle with standard ergometer for physiological measurements associated with maximum effort
【24h】

The validity of Keiser-M3 stationary bicycle with standard ergometer for physiological measurements associated with maximum effort

机译:Keizer-M3固定式自行车用标准测力计的有效性,用于与最大努力相关的生理测量

获取原文
           

摘要

Aim:This study aims to investigate the concordance between two cycle ergometers for variables measured in the test of maximum incremental effort.Methods:This correlation study enrolled 15 inactive women (19,2 ± 4,0 years old). At random, the participants performed two maximal effort incremental tests (MEIT), using cycle ergometers (Keiser-M3 and Ergo-167) on different days with a minimum interval of 72 hours. The test had stages of two minutes, and two-step increments were carried out at the end of each stage. Lactate concentration ([LAC]), and rated perceived exertion (RPE) were collected, in addition to monitoring oxygen uptake (VO2) and heart rate (HR). The Paired t-test was carried out to compare physiologic variables, Lin's test was used for correlation, and Bland Altman was used to measuring concordances among variables.Results:The correlations between physiologic parameters were considered strong for HR on the anaerobic threshold (Keiser M3 = 146 ± 14 bpm; Ergo-167 = 149 ± 9 bpm; r = 0.762), greater blood lactate value (Keiser M3 = 9,97 ± 2,51 mmol/L; Ergo-167 = 9.71 ± 2.56 mmol/L; r = 0.820), VO2max (Keiser M3 = 38,37 ± 6,97 mL/kg/min; Ergo-167 = 36.06 ± 8.4 mL/kg/min; r = 0,806) and HRmax (Keiser M3 = 186 ± 53 bpm; Ergo-167 = 188 ± 11 bpm; r = 0.716).Conclusion:The results show the feasibility of using the cycle ergometer Keiser, model M3, to perform the maximal effort incremental test, whereas there was high concordance in the physiologic responses in both ergometers for inactive women.
机译:目的:本研究旨在调查在最大增量努力测试中测量的两个循环计力计之间的一致性。方法:这种相关性研究注册了15名非活动女性(19,2±4,0岁)。随机,参与者在不同的日子上使用循环计量计(Keizer-M3和Ergo-167)进行两次最大努力增量测试(Meit),最小间隔为72小时。测试具有两分钟的阶段,并且在每个阶段结束时进行两步增量。除了监测氧气吸收(VO2)和心率(HR)之外,收集乳酸浓度(β)和额定感知的劳动(RPE)。进行配对的T检验以比较生理变量,Lin的测试用于相关性,并且Bland Altman用于测量变量之间的一致性。结果:在厌氧阈值上认为生理参数之间的相关性(Keizer M3 = 146±14 bpm; rgo-167 = 149±9 bpm; r = 0.762),血液乳酸率高(Keizer M3 = 9,97±2,51mmol / L; Ergo-167 = 9.71±2.56mmol / L; r = 0.820),VO2max(Keizer M3 = 38,37±6,97 ml / kg / min; ergo-167 = 36.06±8.4 ml / kg / min; r = 0,806)和hrmax(Keizer m3 = 186±53 bpm ; ergo-167 = 188±11 bpm; r = 0.716)。结论:结果表明使用循环计力计Keizer,型号M3进行最大努力增量测试的可行性,而在生理反应中有很高的一致性两者都是非活跃女性的。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号