首页> 外文期刊>Frontiers in Veterinary Science >Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats
【24h】

Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats

机译:临床健康猫肝脏二维剪切波弹性成像的可行性和可靠性

获取原文
获取外文期刊封面目录资料

摘要

Given the broad overlap of normal and abnormal liver tissue in the subjective evaluation of the liver in conventional B-mode ultrasonography, there is a need for a non-invasive and quantitative method for the diagnosis of liver disease. Novel two-dimensional shear-wave elastography can measure tissue stiffness by propagation of the shear-wave induced using acoustic radiation force impulse in real-time. To the best of our knowledge, two-dimensional shear wave measurement of the liver in cats has not been reported to date. This study assessed the feasibility, reliability, normal values, and related influencing factors of two-dimensional shear-wave elastography for assessment of the feline liver, without anesthesia and breath-holding. Two-dimensional shear-wave ultrasonography was performed by two evaluators at the right and left sides of the liver. Twenty-nine client owned clinically healthy adult cats were included. The means and standard deviations for the shear-wave speed and stiffness in the right liver were 1.52 ± 0.13 m/s and 6.94 ± 1.26 kPa, respectively, and those for the left liver were 1.61 ± 0.15 m/s and 7.90 ± 1.47 kPa, respectively. Shear-wave speed (P = 0.005) and stiffness (P = 0.002) were significantly lower in the right liver when compared to the left. The intraclass correlation value for liver stiffness was 0.835 and 0.901 for the right and left liver, respectively, indicating high interobserver agreement. Age, weight, body condition score (BCS), gabapentin administration, and measurement depths were not significantly correlated with liver stiffness or elastography measurements (P 0.05). Our findings suggest that two-dimensional shear-wave elastography measurements of the liver are not influenced significantly by age, weight, or BCS, and can be reliably performed without anesthesia and breath-holding in cats. The values determined here can help form the basis for reference elastography values for evaluation of the feline liver.
机译:鉴于常规B模式超声中肝脏的主观评价中正常和异常肝组织的广泛重叠,需要一种用于肝脏疾病的非侵入性和定量方法。新型二维剪切波弹性显影可以通过实时使用声学辐射力脉冲诱导的剪切波传播来测量组织刚度。据我们所知,迄今为止尚未报告猫的二维剪力波测量猫的肝脏。本研究评估了二维剪切波弹性显影的可行性,可靠性,正常值和相关影响因素,用于评估猫肝脏肝脏,没有麻醉和呼吸持有。二维剪切波超声检查由肝脏右侧和左侧的两个评估员进行。包括二十九名客户拥有的临床健康成年猫。右肝脏剪切波速度和刚度的装置和标准偏差分别为1.52±0.13 m / s和6.94±1.26kPa,左肝脏的偏差为1.61±0.15 m / s和7.90±1.47 kPa , 分别。与左侧相比,剪切波速度(P = 0.005)和刚度(p = 0.002)在右侧肝脏显着降低。肝硬化的腹部相关值分别为左右肝脏的0.835和0.901,表示高interobserver协议。年龄,体重,身体状况得分(BCS),加巴亨坦给药和测量深度与肝硬化或弹性摄影测量没有显着相关(P> 0.05)。我们的研究结果表明,肝脏的二维剪切波弹性术测量不会受到年龄,体重或BCs的显着影响,并且可以在没有麻醉和猫的呼吸持有的情况下可靠地进行。这里确定的值可以帮助为评估猫肝脏评估的参考弹性造影值的基础。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号