首页> 外文期刊>Frontiers in Public Health >Evaluation of DeChoker, an Airway Clearance Device (ACD) Used in Adult Choking Emergencies Within the Adult Care Home Sector: A Mixed Methods Case Study
【24h】

Evaluation of DeChoker, an Airway Clearance Device (ACD) Used in Adult Choking Emergencies Within the Adult Care Home Sector: A Mixed Methods Case Study

机译:Dechoker评估,用于成人护理家庭部门成人窒息的气道清除装置(ACD):混合方法案例研究

获取原文

摘要

Foreign Body Airway Obstruction (FBAO) is a medical emergency that can result in death, particularly if swift, appropriate action is not taken. It can be a frightening experience for all involved. DeChoker, an Airway Clearance Device (ACD), might provide an additional alternative in the management of choking; however, limited evidence around its safety and effectiveness makes adoption controversial. Objectives: To explore the experiences of health and care professionals who used DeChoker in real-life adult choking emergencies, focusing on the product’s safety, efficacy and ease of application Design: Retrospective mixed methods case study, with multiple embedded units of analysis. Setting: UK adult care homes Participants: 27 incidents of adult choking emergencies self-reported by care home staff where DeChoker was used. This data was augmented by an in-depth exploration of four individual choking incidences. Results: The choking victim’s ages range: 45 to 101 years (mean 79.8 years). The device was reported to have successfully removed the obstruction in 26 of 27 cases, with very few complications or adverse events reported. In 21 of 27 incidents (78%) the victim was not required to visit Accident and Emergency. Qualitative data indicated nursing home staff found the DeChoker easy to use and valued its presence as an adjunct to current guideline procedures. Conclusion: There is a dearth of evidence surrounding the management of choking and little innovation in this area for five decades. This retrospective evaluation contributes to discussion regarding the role ACDs might play in the management of choking, particularly in cases where current choking management guidance are ineffective, insufficient, inappropriate or impractical (e.g. frail or movement restricted people). The interview data presents a view from care home staff that the DeChoker, as an ACD, contributed to saving the life of choking victims.
机译:异物气道阻塞(FBAO)是一种医疗紧急情况,可能导致死亡,特别是如果斯威夫特,则没有采取适当的行动。这可能是所有参与者的可怕体验。 Dechoker是一个气道清关设备(ACD),可能在窒息管理中提供额外的替代方案;但是,周围的安全性和有效性有限,取得了采用争议。目标:探讨使用Devhoker在现实成人窒息的突发事件中使用DeChoker的经验,专注于产品的安全性,有效性和应用设计的易用性:回顾性混合方法案例研究,具有多种嵌入式分析单元。环境:英国成人护理家园参与者:27名成人窒息紧急情况自我报告的成人家庭工作人员,其中使用了Dechoker。通过对四个单独的窒息事件的深入探索,这些数据增强。结果:窒息受害者的年龄范围:45至101岁(平均79.8岁)。据报道该装置成功地除去了26例中的26例,并报告了很少的并发症或不良事件。 21项发生的21项(78%),受害者无需访问事故和紧急情况。定性数据表明护理家庭工作人员发现备忘录易于使用,并将其存在作为当前指南程序的辅助。结论:在这一地区的窒息和创新范围内,有一种缺乏的证据,持续了五十年。这种回顾性评估有助于讨论角色ACD在窒息管理中可能发挥的作用,特别是在当前窒息管理指导无效的情况下,不足,不恰当或不切实际(例如虚弱或受限制的人)。面试数据从护理家庭工作人员看来,作为ACD的辩护者,有助于拯救窒息受害者的生活。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号