首页> 外文期刊>Energy Equipment and Systems >Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran
【24h】

Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran

机译:伊朗克尔曼国内水供暖系统平板和疏散管收集器的比较绩效评估

获取原文
   

获取外文期刊封面封底 >>

       

摘要

This study represents a year-round energy performance of two solar water heating (SWH) systems with a 4m2 flat plate collector (FPC) and an evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on a monthly and yearly basis. The obtained results showed that for an annual total solar insolation of 2056kW.h.m-2, a total of 3577kW.h.y-1 and 4201kW.h.y-1 of heat energy were collected by 4m2 FPC and, ETC systems, respectively. The annual average energy efficiency by the FPC system was 43%, while its annual solar fraction was 50%. The ETC system had 51% energy efficiency with 58% solar fraction. The economic analysis showed that both solar water heating systems are not economically viable under prevailing costs in Iran. Furthermore, according to the obtained results, the FPCs are more favorable than the ETCs due to its economic analysis and energy performance. These results provide useful information for households and policymakers.
机译:该研究代表了两种太阳能热水加热(SWH)系统的全年能源性能,具有4M2平板收集器(FPC)和在相同天气条件下操作的抽空管收集器(ETC)。每月和年度比较两种考虑系统的能量性能。得到的结果表明,对于2056kW.H.M-2的年度总太阳能溶解,分别由4M2 FPC和等等系统收集总量的热能3577kw.h.y-1和4201kw.h.y-1。 FPC系统的年平均能源效率为43%,而其年度太阳能分数为50%。 ETC系统的能效51%,太阳能分数为58%。经济分析表明,在伊朗的主要成本下,太阳能加热系统在经济上不可行。此外,根据所得的结果,由于其经济分析和能量性能,FPC比ETCS更有利。这些结果为家庭和政策制定者提供了有用的信息。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号