首页> 外文期刊>International Journal of Integrated Engineering >Analysis of AC-DC Converter Circuit Performance with Difference Piezoelectric Transducer Array Connection
【24h】

Analysis of AC-DC Converter Circuit Performance with Difference Piezoelectric Transducer Array Connection

机译:差异压电换能器阵列连接的AC-DC转换器电路性能分析

获取原文
   

获取外文期刊封面封底 >>

       

摘要

This research presents a simulation analysis for the AC-DC converter circuit with a different configurations of the array connection of the piezoelectric sensor. The selection of AC-DC converter circuits is full wave bridge rectifier (FWBR), parallel SSHI (P-SSHI) and parallel voltage multiplier (PVM) with array configuration variation in series (S), parallel (P), series-parallel (SP) and parallel-series (PS). The system optimizes with different load configurations ranging from 10 k? to 1 M?. The best configuration of AC-DC converter with an appropriate array piezoelectric connection producing the optimum output of harvested power is presented. According to the simulation results, the harvested power produced by using P-SSHI converter connected with 3 parallel piezoelectric transducer array was 85.9% higher than for PVM and 15.88% higher than FWBR.
机译:该研究介绍了具有不同配置压电传感器的阵列连接的AC-DC转换器电路的仿真分析。 AC-DC转换器电路的选择是全波桥式整流器(FWBR),并联SSHI(P-SSHI)和并联电压倍增器(PVM),阵列配置变化串联(S),并联(P),串联( SP)和并联系列(PS)。系统优化了不同的负载配置,范围从10 k?到1米?呈现了具有适当阵列压电连接的AC-DC转换器的最佳配置,产生收获功率的最佳输出。根据仿真结果,使用与3平行压电传感器阵列连接的P-SSHI转换器产生的收获功率高于PVM的85.9%,高于FWBR的15.88%。