摘要

The European Union requires that benzene in the air is continuously measured due to its toxicity and widespread presence in the population nuclei, mainly motivated by vehicle emissions. The reference measuring technique is gas chromatography (GC). Automatic chromatographs used in monitoring stations must verify the operating conditions established in Standard EN 14662 part 3, which includes a type approval section with a number of tests that analysers must pass. Among these tests, the potential interference of a number of compounds is evaluated. The 2005 version of the mentioned standard requires the evaluation of the potential interference of tetrachloromethane (TCM). The 2015 version eliminates TCM as a potential interferent. Although most consumer uses of TCM have been banned, recent studies have measured significant concentrations of TCM in the air. In this paper, the potential interference of TCM in benzene measurements obtained with gas chromatography coupled to a photoionisation detector (GC-PID) has been investigated. Our study shows that the simultaneous presence of benzene and TCM causes a significant decrease in benzene readings. For TCM concentrations of 0.7μgm?3 (typical of urban areas) and 4.5μgm?3 (detected in the vicinity of landfills), the relative errors in benzene measurements were 34% and 70%, respectively, which are far too high compared to the maximum overall uncertainty allowed for benzene measurements (25%). Possible mechanisms to qualitatively and quantitatively explain the behaviour of the PID when measuring benzene with and without TCM have been proposed.
机译:欧洲联盟要求由于其毒性和广泛存在于人群核,主要是由车辆排放而导致的空气中的苯不断测量。参考测量技术是气相色谱(GC)。监控站中使用的自动色谱仪必须验证标准EN 14662第3部分中建立的操作条件,其中包括具有多个测试的类型批准部分,分析仪必须通过。在这些测试中,评估许多化合物的潜在干扰。提到的标准的2005年版本需要评估四氯甲烷(TCM)的潜在干扰。 2015年版本消除了TCM作为潜在的干扰。虽然大多数消费者使用中医用途已被禁止,但最近的研究已经在空中测量了显着的TCM浓度。本文研究了通过偶联与光离析检测器(GC-PID)的气相色谱法获得的TCM在苯测量中的潜在干扰。我们的研究表明,苯和TCM的同时存在导致苯读数的显着降低。对于TCM浓度为0.7μgm?3(典型的城市地区)和4.5μgm?3(在垃圾填埋场附近检测到),苯测量中的相对误差分别为34%和70%,而与之过得太高苯测量允许的最大不确定性(25%)。已经提出了在测量具有和不具有TCM时苯时定性和定量解释PID的行为的可能机制。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号