...
首页> 外文期刊>Atmospheric Measurement Techniques Discussions >Integration and calibration of non-dispersive infrared (NDIR) CO2 low-cost sensors and their operation in a sensor network covering Switzerland
【24h】

Integration and calibration of non-dispersive infrared (NDIR) CO2 low-cost sensors and their operation in a sensor network covering Switzerland

机译:非分散红外线(NDIR)CO2低成本传感器的集成与校准及其在瑞士传感器网络中的操作

获取原文

摘要

More than 300 non-dispersive infrared (NDIR) CO2 low-cost sensors labelled as LP8 were integrated into sensor units and evaluated for the purpose of long-term operation in the Carbosense CO2 sensor network in Switzerland. Prior to deployment, all sensors were calibrated in a pressure and climate chamber and in ambient conditions co-located with a reference instrument. To investigate their long-term performance and to test different data processing strategies, 18 sensors were deployed at five locations equipped with a reference instrument after calibration. Their accuracy during 19 to 25?months deployment was between 8 and 12ppm. This level of accuracy requires careful sensor calibration prior to deployment, continuous monitoring of the sensors, efficient data filtering, and a procedure to correct drifts and jumps in the sensor signal during operation. High relative humidity (~85?%) impairs the LP8 measurements, and corresponding data filtering results in a significant loss during humid conditions. The LP8 sensors are not suitable for the detection of small regional gradients and long-term trends. However, with careful data processing, the sensors are able to resolve CO2 changes and differences with a magnitude larger than about 30ppm. Thereby, the sensor can resolve the site-specific CO2 signal at most locations in Switzerland. A low-power network (LPN) using LoRaWAN allowed for reliable data transmission with low energy consumption and proved to be a key element of the Carbosense low-cost sensor network.
机译:超过300个非分散红外(NDIR)CO2低成本传感器标记为LP8,集成到传感器单元中,并在瑞士的Carbosense CO2传感器网络中进行了长期运行的目的。在部署之前,所有传感器的压力和气候室内校准,以及与参考仪器共同定位的环境条件。为了调查它们的长期性能并测试不同的数据处理策略,在校准后的五个位置部署了18个传感器。他们的准确性在19到25岁以下?几个月部署在8到12ppm之间。这种精度级别需要仔细的传感器校准在部署之前,连续监控传感器,高效数据过滤以及在操作期间纠正漂移并跳转在传感器信号中的过程。高相对湿度(〜85〜%)损害LP8测量,并且相应的数据滤波导致潮湿条件下的显着损失。 LP8传感器不适合检测小区域梯度和长期趋势。然而,通过仔细数据处理,传感器能够解析CO2变化和差异,其大于约30ppm。因此,传感器可以在瑞士最多的位置解决特定于站点的CO2信号。使用LoraWan的低功耗网络(LPN)允许具有低能量消耗的可靠数据传输,并被证明是销钉低成本传感器网络的关键元件。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号