首页> 外文期刊>Atmospheric Chemistry and Physics Discussions >Simultaneous trace gas measurements using two Fourier transform spectrometers at Eureka, Canada during spring 2006, and comparisons with the ACE-FTS
【24h】

Simultaneous trace gas measurements using two Fourier transform spectrometers at Eureka, Canada during spring 2006, and comparisons with the ACE-FTS

机译:在2006年春季,加拿大尤里卡,加拿大的两个傅里叶变换光谱仪同时痕量气体测量,以及与ACE-FTS的比较

获取原文
           

摘要

The 2006 Canadian Arctic ACE (Atmospheric Chemistry Experiment) Validation Campaign collected measurements at the Polar Environment Atmospheric Research Laboratory (PEARL, 86.42° W, 80.05° N, 610 m a.s.l.) at Eureka, Canada from 17 February to 31 March 2006. Two of the ten instruments involved in the campaign, both Fourier transform spectrometers (FTSs), were operated simultaneously, recording atmospheric solar absorption spectra. The first instrument was an ABB Bomem DA8 high-resolution infrared FTS. The second instrument was the Portable Atmospheric Research Interferometric Spectrometer for the Infrared (PARIS-IR), the ground-based version of the satellite-borne FTS on the ACE satellite (ACE-FTS). From the measurements collected by these two ground-based instruments, total column densities of seven stratospheric trace gases (O3, HCl, ClONO2, HF, HNO3, NO2, and NO) were retrieved using the optimal estimation method and these results were compared. Since the two instruments sampled the same portions of atmosphere by synchronizing observations during the campaign and used consistent retrieval parameters, the biases in retrieved columns from the two spectrometers represent the instrumental differences. Mean differences in total column densities of O3, HCl, ClONO2, HF, HNO3, and NO2 from the observations between PARIS-IR and the DA8 FTS are 2.8 %, 3.2 %, 4.3 %, 1.5 %, 1.9 %, and 0.1 %, respectively. Partial column results from the ground-based spectrometers were also compared with partial columns derived from ACE-FTS version 2.2 (including updates for O3) profiles. Mean differences in partial column densities of O3, HCl, ClONO2, HF, HNO3, NO2, and NO from the measurements between ACE-FTS and the DA8 FTS are 5.9 %, 8.5 %, 11.8 %, 0.9 %, 6.6 %, 21.6 % and 7.6 % respectively. Mean differences in partial column densities of O3, HCl, ClONO2, HF, HNO3, NO2 from the measurements between ACE-FTS and the PARIS-IR are 5.2 %, 4.6 %, 2.3 %, 4.7 %, 5.7 % and 11.9 %, respectively. This work provides further evidence of the reliability of ACE-FTS measurements from the first three years of on-orbit observations. Column densities of O3, HCl, ClONO2, and HNO3 from the three FTSs were normalized with respect to HF and used to compare the time evolution of the chemical constituents in the atmosphere over Eureka during spring 2006.
机译:2006年2006年CANADIAN ARCTIC ACE(大气化学实验)从2006年2月17日至2006年3月31日期间在加拿大尤里卡的极地环境大气研究实验室(PEARL,86.42°W,80.05°N,610米ASL)的验证活动收集了竞选活动。涉及活动的十种仪器,傅立叶变换光谱仪(FTS)同时操作,记录大气太阳能吸收光谱。第一仪器是ABB Bomem DA8高分辨率红外FTS。第二仪器是用于红外(Paris-IR)的便携式大气研究干涉谱仪,卫星卫星(ACE-FTS)上的卫星FTS的地面版本。从由这两个地基仪器收集的测量,使用最佳估计方法检索七种平流层痕量气体(O 3,HCl,ClonO 2,HF,HNO 3,NO 2和NO)的总色谱柱密度,并比较这些结果。由于两种仪器通过在广告系列期间同步观察和使用一致的检索参数来采样相同的大气部分,因此来自两个光谱仪的检索列中的偏差表示仪器差异。从巴黎-R和DA8 FTS之间观察结果的O3,HCl,Clono2,HF,HNO3和No2的总色谱柱密度的平均差异为2.8%,3.2%,4.3%,1.5%,1.9%和0.1%,分别。也与从ACE-FTS 2.2(包括O3)配置文件的部分列进行比较部分列的部分柱的结果。 O3,HCl,Clono2,HF,HNO3,NO2和NO.SCE-FTS和DA8 FTS的测量的部分柱密度的平均差异为5.9%,8.5%,11.8%,0.9%,6.6%,21.6%分别为7.6%。 O3,HCl,Clono2,HF,HNO3,NO 2之间的部分柱密度的平均差异分别为5.2%,4.6%,2.3%,4.7%,5.7%和11.9% 。这项工作提供了来自在轨道观测的前三年的ACE-FTS测量的可靠性提供了进一步的证据。来自三种FTS的O 3,HCl,ClonO 2和HNO3的柱密度相对于HF标准化,并用于比较2006春季尤里卡在尤里卡的大气中的化学成分的时间演变。
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号