Aim: The purpose of the current study was to conduct a systematic review of the published literature to evaluate the diagnostic accuracy of FDG-PET, PTE/CT, MRI and scintigraphy for multiple myeloma related bone disease. Methods: Through a search of PubMed, EMBASE, and the Cochrane Library, two reviewers independently assessed the methodological quality of each study. We estimated pooled sensitivity, specificity, positive and negative likelihood ratios (PLR and NLR), and two sample Z-tests were conducted to evaluate for differences in sensitivity, specificity, area under the curve (AUC), and the index between any two diagnostic modalities. Results: A total of 17 studies were reviewed. The MRI had a pooled sensitivity of 0.88, specificity of 0.68, AUC of 0.897, and index of 0.828, whereas for MIBI, the corresponding values were 0.98, 0.90, 0.991, and 0.962, respectively, and for bone scan, they were 066, 0.83, 0.805, and 0.740, respectively. The corresponding values of MIBI were 0.98, 0.90, 0.991, and 0.962, respectively. For PET and PET/CT, the values were 0.91, 0.69, 0.927 and 0.861, respectively. Statistically significant differences were not found in the sensitivity, specificity, AUC, and index between MRI, scintigraphy, FDG-PET and PET/CT. Conclusions: On the condition that X ray is taken as a reference in our study, we suggested that FDG-PET, PTE/CT, MRI and scintigraphy are all associated with high detection rate of bone disease in patients with MM. Thus, in clinical practice, it is recommended that we could choose these tests according to the condition of the patient.
机译:目的:目前的研究目的是对公开文献进行系统审查,以评估FDG-PET,PTE / CT,MRI和闪烁的诊断准确性对多种骨髓瘤相关骨病的思考。方法:通过搜索PubMed,Embase和Cochrane图书馆,两位审阅者独立评估了每项研究的方法论质量。我们估计汇集敏感性,特异性,正和负似然比(PLR和NLR),并进行了两个样品Z检验,以评估曲线(AUC)下的敏感性,特异性,面积的差异,以及任何两个诊断的指标方式。结果:综述了17项研究。 MRI的汇集灵敏度为0.88,特异性为0.68,AUC,0.897的指数,0.828,而对于MIBI,相应的值分别为0.98,0.90,0.991和0.962,以及骨扫描,它们为066,它们为066, 0.83,0.805和0.740分别。 MIBI的相应值分别为0.98,0.90,0.991和0.962。对于PET和PET / CT,值分别为0.91,0.69,0.927和0.861。在MRI,Scintaphy,FDG-PET和PET / CT之间的敏感性,特异性,AUC和指数中未发现统计学上显着的差异。结论:关于X射线作为我们研究参考的条件,我们建议FDG-PET,PTE / CT,MRI和Scintigraphy均与MM患者患者的骨病高检测率相关。因此,在临床实践中,建议我们根据患者的状况选择这些测试。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号