OBJECTIVE:The aim of this study was to analyze the contamination rates of the skin under the iodophor-impregnated plastic adhesive drape (IOD) at the time of incision closure in total hip arthroplasty (THA).METHODS:A total of 225 patients undergoing primary THA (28 men, 197 women; mean age=65 years; age range=30-85) were included in this study. After asepsis using a solution of 1% chlorhexidine with 83% alcohol by volume, the surgical site was painted with a 10% povidone-iodine solution, and IOD was attached tautly at the start of surgery. Swabs of the surgical site were collected as follows: swab A from the skin before IOD application, swab B from the surface of the IOD at the time of incision closure, and swab C from the skin after peeling back the IOD. The obtained samples were promptly sent for microbiological analysis. The contamination rate was determined for swabs A, B, and C, and the contamination rate of swab C was compared with that of swabs A and B, and the bacterial species were identified.RESULTS:Positive cultures were seen in 8 cases (3.6%) for swab A, 10 cases (4.4%) for swab B, and 22 cases (9.8%) for swab C. The contamination rate of swab C was significantly higher than that of swabs A (p=0.008) and B (p=0.028). Coagulase-negative Staphylococcus (n=10) and Cutibacterium acnes (n=7) were the most frequently cultured microorganisms from swab C.CONCLUSION:In THA, the contamination rate of the skin after peeling off the IOD before incision closure was higher than that of the skin immediately after sterilization with povidone-iodine and higher than that on the IOD at the time of incision closure. The detected bacterial species were considered clinically significant pathogens. Preventive measures against infection, such as minimizing stripping of the IOD or re-sterilizing bare skin after IOD stripping, should be instituted in consideration of these findings when performing THA using IOD.
机译:目的:本研究的目的是在肝脏浸渍的塑料粘合剂悬垂(IOD)下,在整个髋关节置换术(THA)中的碘期浸渍塑料胶羊(IOD)下的污染率。方法:总共225名接受初级的患者Tha(28名男子,197名女性;平均年龄= 65岁;年龄范围= 30-85)纳入本研究。在使用1%氯己定量的溶液通过体积溶液溶液后,手术部位用10%的povidone-碘溶液涂上涂料,并且在手术开始时加紧碘。外科部位的拭子如下收集:从碘施用前从皮肤拭子,在切口闭合时从IOD的表面的拭子B,并在剥离IOD后从皮肤拭子。迅速发送所得样品进行微生物分析。测定拭子A,B和C测定污染率,并将拭子C的污染速率与拭子A和B的污染率进行比较,并且鉴定细菌种类。结果:8例中可以看到阳性培养物(3.6%) )对于拭子B的拭子A,Swab B的10例(4.4%),22例(9.8%)用于拭子C.拭子C的污染率明显高于拭子A(p = 0.008)和B(P = 0.028)。凝固酶阴性葡萄球菌(n = 10)和切割杆菌(n = 7)是来自拭子C的最常培养的微生物。结论:在切口闭合之前剥离IOD后皮肤污染率高于此用Povidone-碘灭菌后立即皮肤,在切口闭合时高于IOD上的皮肤。检测到的细菌物种被认为是临床显着的病原体。应在使用IOD执行THA时考虑这些发现,在使用IOD执行THA时,对防止感染或在IOD剥离后重新灭菌皮肤剥离裸露皮肤的预防措施。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号