首页> 外文期刊>Acta Orthopaedica et Traumatologica Turcica >Relationship between the tilt angle of bipolar radial head prostheses and radiological radiocapitellar instability
【24h】

Relationship between the tilt angle of bipolar radial head prostheses and radiological radiocapitellar instability

机译:双极径向头倾斜角度与放射线放射辐射肌肉不稳定性的关系

获取原文
           

摘要

OBJECTIVE:This study aimed to radiologically assess the relationship between the tilt angle of the bipolar radial head prostheses and radiocapitellar instability.METHODS:In this radiological study, 28 consecutive patients (13 females and 15 males: mean age=47 years and age range=23-77 years) who underwent cemented bipolar radial head arthroplasty (Judet CRF II) because of comminuted radial head fracture with elbow instability were retrospectively reviewed.RESULTS:There was excellent intra- and interobserver reliability for the measurements of the tilt angle and the radiocapitellar distance. ICC for interobserver reliability of the tilt angle was 0.93, and ICC for intraobserver reliability for the 2 observers was 0.96 and 0.97, respectively. ICC for interobserver reliability of the radiocapitellar distance was 0.87, and ICC for intraobserver reliability for the 2 observers was 0.91 and 0.93, respectively. The mean tilt angle was 17.6° (range=1°-35°), and the mean radiocapitellar distance was 8 mm (range=1-17 mm). Pearson's correlation revealed a strong significant positive correlation between the tilt angle and the radiocapitellar distance (r=0.77 and p0.001).CONCLUSION:Evidence from this study has demonstrated a strong positive correlation between the tilt angle of bipolar radial head prostheses and radiocapitellar instability. The tilt angle can be used as an indicator of radiocapitellar joint instability following bipolar radial head prostheses.LEVEL OF EVIDENCE:Level IV, Diagnostic study.
机译:目的:本研究旨在放射学评估双极桡骨头假体和radiocapitellar instability.METHODS的倾斜角之间的关系:连续28名患者(女性13和15层的男性在该放射研究,:平均年龄= 47岁,年龄范围= 23-77岁)谁接受胶结双极桡骨头关节成形术,因为粉碎桡骨头骨折与肘关节不稳定的(Judet CRF II)进行回顾性reviewed.RESULTS:有优异的细胞内和观察者间的倾斜角和radiocapitellar的测量可靠性距离。 ICC为倾斜角度的观察者间可靠性为0.93,和对于ICC观察者为2个观察员可靠性分别为0.96和0.97。 ICC为radiocapitellar距离的观察者间可靠性为0.87,和对于ICC观察者为2个观察员可靠性分别为0.91和0.93。平均倾斜角为17.6°(范围= 1°-35°),和平均radiocapitellar距离为8毫米(范围= 1-17毫米)。 Pearson相关揭示的倾斜角和所述radiocapitellar距离(r = 0.77和p <0.001)之间有很强的显著正相关。结论:本研究的证据表明双极桡骨头假体和radiocapitellar不稳定的倾斜角之间的很强的正相关。的倾斜角度可被用作下列双极桡骨头prostheses.LEVEL证据进行radiocapitellar关节不稳定的指示器:IV级,诊断研究。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号