Stability-Indicating HPLC Methods for the Quantification of Cyproheptadine Hydrochloride, Vitamins B1, B5 And B6 in Tablets using RP-HPLC with UV Detection

机译:使用RP-HPLC具有UV检测的平板电脑中盐酸盐酸盐,维生素B1,B5和B6的稳定性稳定性的HPLC方法

获取原文
           

摘要

The availability of reliable and fast analytical method is crucial for the quality control of multi-API in a single dosage form. Herein, two methods have been developed and validated for the determination of Cyproheptadine hydrochloride (CH), Thiamine mononitrate (Vit. B 1 ), Calcium pantothenate (Vit. B 5 ) and Pyridoxine hydrochloride (Vit. B 6 ) in uncoated tablets. To assay the vitamins, a mobile phase combination of Phosphate buffer pH 3.5 and Methanol in the ratio 93:7, using Eurospher ODS (150 x 4.5mm) as the stationary phase with a flow rate set at 1.0 mL/min at ambient temperature conditions was adopted. Wavelength of detection was 270 nm with a run time of 0.00 to 5.50 minutes for Thiamine mononitrate and Pyridoxine hydrochloride, and 205 nm from 5.50 to 11.00 minutes for Calcium pantothenate. A good resolution and a short run time of 11 minutes were achieved with the validated conditions. The retention times of Thiamine mononitrate, Pyridoxine hydrochloride and Calcium pantothenate were 2.823±0.020, 4.184±0.007 and 10.025±0.015 respectively. The mobile phase for Cyproheptadine HCl was methanol and an ion-pairing solution (70:30), set at a flow rate of 1mL/min, a runtime of 8 minutes, an injection volume of 20 μL and a wavelength of 285 nm using Eurospher ODS (150 x 4.5 mm) as the stationary phase. The retention time for Cyproheptadine HCl was 4.961±0.006. Both methods were found to be specific, robust, accurate and precise over the concentration ranges of 0.0192 mg/mL–0.0288 mg/mL for Thiamine mononitrate, 0.0128–0.0192 mg/mL for Pyridoxine hydrochloride, 0.032–0.048 mg/mL for Calcium pantothenate and 0.032-0.048 mg/mL for Cyproheptadine hydrochloride. The Correlation Coefficient (r 2 ) for Cyproheptadine hydrochloride, Thiamine mononitrate, Pyridoxine hydrochloride and Calcium pantothenate were greater than 0.999. The purpose of this study was to develop and validate simple HPLC methods for the estimation of Cyproheptadine hydrochloride, Vitamins B 1 , B 5 and B 6 in combined dosage forms. The proposed methods were found to be precise, specific, accurate and robust for the estimation of Cyproheptadine hydrochloride, Vitamins B 1 , B 5 and B 6.
机译:可靠和快速分析方法的可用性对于单一剂型中多API的质量控制至关重要。在此,已经开发并验证了两种方法,用于测定未涂层片剂中的硫酸己酰盐酸盐(CH),硫胺素硫酸盐(VIT.B 1),泛酸钙(Vit.B 5)和吡哆醇盐酸盐(Vit.B 6)。为了测定维生素,在比率93:7中的磷酸盐缓冲液pH 3.5和甲醇的流动相组合,使用Eurosher ODS(150×4.5mm)作为固定相,在环境温度条件下设定在1.0ml / min的流速下被采纳。检测波长为270nm,运行时间为0.00-5.50分钟,氨基硝酸盐和吡哆醇盐酸盐,205nm,钙肝钙酸钙。通过验证条件实现了良好的分辨率和11分钟的短暂时间。硫胺素硝酸盐,吡哆醇盐酸盐和肝钙酸钙的保留时间分别为2.823±0.020,4.184±0.007和10.025±0.015。用于硫代庚酮HCl的流动相是甲醇和离子配对溶液(70:30),以1ml / min的流速设定,8分钟的运行时间,注射体积为20μL,使用Eurshher的285nm的波长为285nm ODS(150 x 4.5 mm)作为固定阶段。硫代庚酮HCl的保留时间为4.961±0.006。发现这两种方法都是特异性,鲁棒,精确,精确的浓度范围为0.0192mg / ml-0.0288mg / ml的硫胺硝酸盐,0.0128-0.0192mg / ml的吡哆醇盐酸钙,0.032-0.048mg / ml,用于钙肝钙酸钙盐酸碘化己酰胺0.032-0.048 mg / ml。盐酸亚硫酸盐,纯硝酸盐,吡哆醇盐酸钙和碳酸钙的相关系数(R 2)大于0.999。本研究的目的是开发和验证用于估计富含剂型的硫酸盐酸盐,维生素B 1,B 5和B 6的简单HPLC方法。发现所提出的方法是钙庚啶盐酸盐,维生素B 1,B 5和B 6的精确,特异性,准确和稳健的精确,具体,准确和鲁棒。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号