首页> 外文期刊>BMC Ophthalmology >Comparison of two different optical coherence tomography angiography devices in detecting healthy versus glaucomatous eyes – an observational cross-sectional study
【24h】

Comparison of two different optical coherence tomography angiography devices in detecting healthy versus glaucomatous eyes – an observational cross-sectional study

机译:两种不同光学相干断层造影血管造影器件检测健康与胶石眼的血管造影装置 - 一种观察横截面研究

获取原文
           

摘要

To understand the differences between two different optical coherence tomography angiography (OCTA) devices in detecting glaucomatous from healthy eyes by comparing their vascular parameters, diagnostic accuracy and test-retest reliability. A cross-sectional observational study was performed on healthy and glaucoma subjects, on whom two sets of OCTA images of optic disc and macula were acquired using both AngioVue (Optovue, USA) and Swept Source (Topcon, Japan) OCTA devices during one visit. A novel in-house software was used to calculate the vessel densities. Diagnostic accuracy of the machines in differentiating healthy versus glaucomatous eyes was determined using area under the receiver operating characteristic curve (AUROC) and test-retest repeatability of the machines was also evaluated. A total of 80 healthy and 38 glaucomatous eyes were evaluated. Glaucomatous eyes had reduced mean vessel density compared to healthy controls in all segmented layers of the optic disc and macula using AngioVue (p?≤?0.001). However, glaucomatous eyes had higher mean vessel density on optic disc scans using Swept Source, with lack of statistically significant difference between healthy and glaucomatous eyes. The AUROC showed better diagnostic accuracy of AngioVue (0.761–1.000) compared to Swept Source (0.113–0.644). The test-retest reliability indices were generally better using AngioVue than Swept Source. AngioVue showed better diagnostic capability and test-retest reliability compared to Swept Source. Further studies need to be undertaken to evaluate if there is any significant difference between the various machines in diagnosing and monitoring glaucoma.
机译:通过比较它们的血管参数,诊断的准确性和重测可靠性理解在检测从健康的眼睛青光眼两个不同的光学相干断层扫描血管造影(OCTA)设备之间的差异。的截面观察研究对健康和青光眼受试者进行,在其中使用两个AngioVue(Optovue,USA)获得的和一个旅行期间扫频光源(拓普康,日本)OCTA设备两套视盘和黄斑OCTA图像。一种新的内部软件来计算血管密度。使用接收器操作特征曲线(AUROC)和重测机器的重复性下面积也评价测定在区分健康与青光眼的机器的诊断的准确性。总共有80名健康和38青光眼患者进行了评价。相比于使用AngioVue(P 2≤?0.001)视神经盘和黄斑的所有分段的层健康对照青光眼已减小的平均血管密度。然而,青光眼对视神经乳头扫描较高的平均血管密度使用扫频光源,与缺乏健康和青光眼患者之间统计学显著差异。相比扫频光源(0.113-0.644)的AUROC表明AngioVue(0.761-1.000)的更好的诊断准确性。重测可靠性指标普遍较好使用AngioVue比扫频光源。 AngioVue相比显示出扫频光源更好的诊断能力和重测信度。进一步的研究需要进行了评估,如果在诊断和监测青光眼各种机器之间的任何显著差异。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号