摘要

Tissue oximetry can assist in diagnosis and prognosis of many diseases and enable personalized therapy. Previously, we reported the ability of hexamethyldisiloxane (HMDSO) for accurate measurements of tissue oxygen tension (pOsub2/sub) using Proton Imaging of Siloxanes to map Tissue Oxygenation Levels (PISTOL) magnetic resonance imaging. Here we report the feasibility of several commercially available linear and cyclic siloxanes (molecular weight 162-410?g/mol) as PISTOL-based oxygen reporters by characterizing their calibration constants. Further, field and temperature dependence of pOsub2/sub calibration curves of HMDSO, octamethyltrisiloxane (OMTSO) and polydimethylsiloxane (PDMSO) were also studied. The spin-lattice relaxation rate Rsub1/sub of all siloxanes studied here exhibited a linear relationship with oxygenation (Rsub1/sub?=?A'?+?B'*pOsub2/sub) at all temperatures and field strengths evaluated here. The sensitivity index η(?=?B'/A') decreased with increasing molecular weight with values ranged from 4.7?×?10sup-3/sup-11.6?×?10sup-3/sup torrsup-1/sup at 4.7?T. No substantial change in the anoxic relaxation rate and a slight decrease in pOsub2/sub sensitivity was observed at higher magnetic fields of 7?T and 9.4?T for HMDSO and OMTSO. Temperature dependence of calibration curves for HMDSO, OMTSO and PDMSO was small and simulated errors in pOsub2/sub measurement were 1-2 torr/°C. In summary, we have demonstrated the feasibility of various linear and cyclic siloxanes as pOsub2/sub-reporters for PISTOL-based oximetry.
机译:组织血氧基可以帮助诊断和预后许多疾病并实现个性化治疗。以前,我们报道了六甲基二硅氧烷(HMDSO)的能力,用于使用硅氧烷的质子成像进行组织氧张力(PO 2 )来映射组织氧合水平(手枪)磁共振成像。在这里,我们通过表征其校准常数来报告几种市售线性和环状硅氧烷(分子量162-410μm≤g/ mol)作为Pistol的氧气记者的可行性。此外,还研究了HMDSO,八烷基三硅氧烷(OMTSO)和聚二甲基硅氧烷(PDMSO)的PO 2 校准曲线的田间和温度依赖性。在这里研究的所有硅氧烷的旋转晶格弛豫率R 1 与氧合形成线性关系(R 1 =Δa'+?b'* po 2 )。敏感性指数η(α=Δb'/ a')随着分子量的增加而增加,值范围为4.7Ω×10 -3?×10 -3 torr -1 在4.7?t。对于HMDSO和OMTSO的较高磁场,观察到缺氧弛豫率和PO 2 敏感性略微降低的大量变化。 HMDSO,OMTSO和PDMSO的校准曲线的温度依赖性小而且PO 2 测量中的模拟误差为1-2托/°C。总之,我们已经证明了各种线性和环氧化硅氧烷的可行性作为POP 2 -reporters用于pistol基血氧乙液。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号