首页> 外文期刊>MATEC Web of Conferences >Aerodynamic numerical calculations of air-cooled condensers and dry cooling towers at different wind velocities and multilevel configuration of sections
【24h】

Aerodynamic numerical calculations of air-cooled condensers and dry cooling towers at different wind velocities and multilevel configuration of sections

机译:空气冷凝器的空气动力学数值计算和不同风速下的干燥冷却塔和多级配置

获取原文
           

摘要

Multilevel configuration of heat exchange sections of air-cooled condensers and dry cooling towers with a multi-row arrangement are offered. Results of a research of the combined operation of fans and V-shaped heat exchangers by methods of numerical model operation at wind and without it for three-row sections are given. It is shown that in the presence of wind multilevel configuration of heat exchange sections has advantages over single-level configuration.
机译:提供了一种空气冷凝液和带有多排布置的冷却冷却塔的热交换部分的多级配置。给出了风扇和V形热交换器的组合操作的研究结果,给出了在风中的数值模型操作方法中,没有用于三排部分。结果表明,在风多电平的存在下,热交换部分的各个优于单电平配置。