A concept development of an early warning system for toxic sewage detection

机译:毒性污水检测预警系统的概念发展

获取原文
           

摘要

The article presents a concept of an EWS (early warning system) for toxic sewage detection upstream from Wroclaw Wastewater Treatment Plant. It includes design and construction of three toxicity warning stations, situated in municipal sewage system. Early detection of toxic contaminants provides time for corrective actions. Wastewater toxicity level is based on activated sludge OUR (Oxygen Uptake Rate) measurement. The database of normal level of activated sludge OUR is collected during the measurement initial phase. Hence, if toxic event occurs, device will measure decreased OUR value and WWTP operators will be alarmed. Additionally, flow measurement is carried out. It allows to estimate the volume of a toxic stream. Development of the early warning system requires solving minimum six different scientific and technical issues and is a subject for a complex research project.
机译:本文介绍了弗罗茨瓦夫废水处理厂上游毒性污水检测的EWS(预警系统)的概念。它包括三个毒性警告站的设计和施工,位于市政污水系统。早期检测有毒污染物为纠正措施提供了时间。废水毒性水平是基于激活的污泥我们的(氧气吸收率)测量。在测量初始阶段期间收集正常活性污泥水平的数据库。因此,如果发生有毒事件,设备将衡量减少我们的价值和WWTP运算符将被警告。另外,进行流量测量。它允许估计有毒流的体积。早期预警系统的开发需要解决最少六种不同的科学和技术问题,并且是复杂研究项目的主题。