Evaluation of Healthy Tissue Dose at Different Regions between Volumetric-Modulated Arc Therapy and Intensity-Modulated Radiation Therapy Plans in the Treatment of Various Cancers

机译:对各种癌症的体积调制弧治疗和强度调制放射治疗计划的不同地区健康组织剂量的评价

获取原文

摘要

Background: Radiotherapy plays an important role in the management of cancer. Although the improved technologies increase therapeutic index, different delivery techniques deliver different dose pattern to the healthy tissue within and outside treatment volume. Objective: The objective of this study was to evaluate the low, intermediate, and high dose to healthy tissue within and outside the treatment volume and to find the relation between tumor volume and various doses received healthy tissue volume. Materials and Methods: A total of 150 patients were included. For all patients, planning computed tomography images were acquired. Tumors, critical structures, and healthy tissue volumes at different regions were delineated. Two sets of plans, one with volumetric-modulated arc therapy and another with intensity-modulated radiation therapy (IMRT) were created, optimized for 6 MV photons and dose was calculated. Dosimetry results for tumor, organs at risks (OARs), and healthy tissue from both the techniques were evaluated and compared. Results: Tumor coverage and dose to OARs was significantly better with volumetric-modulated arc therapy (VMAT). Volume of healthy tissue received high-dose within the treatment volume as well as volume of healthy tissue received low and intermediate-dose out of treatment volume were significantly ( P 0.002) lesser with VMAT. Besides, the results showed that as the tumor volume increased, the various dose received healthy tissue volume also increased. Conclusions: VMAT plan can reduce the risk of secondary malignancy while treating different sites of cancer. VMAT is the most appropriate technique than IMRT, especially in the treatment of large tumor volume. Special attention has to be given, especially while treating women and children.
机译:背景:放射疗法在癌症管理中起着重要作用。虽然改进的技术增加了治疗指标,但不同的递送技术将不同的剂量模式传递给健康组织内外的健康组织。目的:本研究的目的是评估治疗体积内外的低,中间和高剂量,并在治疗体积内和肿瘤体积与各种剂量之间的关系接受健康组织体积。材料和方法:共有150名患者。对于所有患者,获得规划计算的层析造影图像。不同地区的肿瘤,关键结构和健康组织体积被描绘。产生两组计划,其中创建了一种具有体积调制的电弧疗法和另一个具有强度调制的放射疗法(IMRT),优化6mV光子并计算剂量。肿瘤的剂量测定结果,在风险(OAR)和来自两种技术的健康组织的肿瘤,并进行比较。结果:肿瘤覆盖率和桨剂量与体积调制的电弧疗法(VMAT)明显更好。健康组织的体积接受治疗体积内的高剂量以及接受低温和中间剂量的健康组织的体积显着(p <0.002)较小,VMAT较小。此外,结果表明,随着肿瘤体积增加,各种剂量接受的健康组织体积也增加。结论:VMAT计划可以降低继发性恶性肿瘤的风险,同时治疗不同癌症部位。 VMAT是最合适的技术而不是IMRT,特别是在治疗大肿瘤体积。必须特别注意,特别是在治疗妇女和儿童时。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号