...
首页> 外文期刊>Journal of Vascular and Interventional Neurology >Comparative Analysis of Unruptured Cerebral Aneurysm Treatment Outcomes and Complications with the Classic versus Flex Pipeline Embolization Devices and Phenom versus Marksman Microcatheter Delivery System: The Role of Microcatheter Choice on Complication Rate
【24h】

Comparative Analysis of Unruptured Cerebral Aneurysm Treatment Outcomes and Complications with the Classic versus Flex Pipeline Embolization Devices and Phenom versus Marksman Microcatheter Delivery System: The Role of Microcatheter Choice on Complication Rate

机译:悬垂性脑动脉瘤治疗结果的比较分析及经典与Flex管道栓塞装置和斑点微导管递送系统的作用:微直接调味对并发症率的作用

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Objective The second-generation pipeline embolization device (PED), flex, has improved opening and resheathing ability compared to the first-generation classic PED device. A previously reported single-institutional study suggests that the PED flex devices are associated with lower rates of complications. However, there was limited discussion regarding the complication rate with respect to microcatheter choice for PED delivery and deployment. The present study aims to evaluate outcomes of aneurysm treatment with PED flex versus classic along with the Phenom microcatheter versus Marksman microcatheter. Methods A retrospective, IRB-approved database of all patients who received a PED classic or PED flex device between January 2012 and July 2018 was analyzed. Microcatheter choice, patient demographics, medical comorbidities, aneurysm characteristics, treatment information, and outcome data were analyzed using univariate analyses. Results A total of 75 PED procedures were analyzed. There was no significant difference in major complications between the PED classic and PED flex. However, those treated using the Marksman microcatheter were more likely to have a major complication (periprocedural hemorrhage or ischemic event; 16.6% vs. 0%, p = 0.0248) than those treated with the Phenom microcatheter. Within the PED flex cohort, all major complications were associated with the Marksman microcatheter ( p = 0.0289). Conclusions The present study does not replicate significantly fewer complications with PED flex but demonstrates a significant reduction in complications with the Phenom microcatheter. Ultimately, this suggests multiple factors are involved in achieving positive outcomes and low complication rates in PED treated unruptured cerebral aneurysms.
机译:目的,与第一代经典PED设备相比,第二代管道栓塞装置(PED),弯曲,具有改进的开口和可剥离能力。先前报道的单一机构研究表明,PED Flex设备与较低的并发率相关。然而,关于PED交付和部署的微直接调度的并发症率有限的讨论。本研究旨在评估用PED Flex与经典的动脉瘤治疗的结果与Phenom Microcatheter与Marksman Microcatheter一起进行。方法分析了2012年1月至2018年1月至2018年1月至2018年1月间接受PED经典或PED Flex设备的所有患者的回顾性的IRB批准的数据库。使用单变量分析分析了微直接调度,患者人口统计学,医疗组合,动脉瘤特征,治疗信息和结果数据。结果共分析了75个PED程序。 PED经典和PED Flex之间的主要并发症没有显着差异。然而,使用Marksman Microcatheter处理的那些更可能具有重大并发症(Periprocent Hemorrhage或缺血事件; 16.6%与0%,p = 0.0248),而不是用Phenom MicroCather处理的那些。在Ped Flex Cohort中,所有主要并发症都与Marksman Microcatheter相关联(P = 0.0289)。结论本研究不复制较少较少的PED Flex并发症,但证明了Phenom MicroCather的并发症的显着降低。最终,这表明多种因素涉及在PED治疗的脑动脉瘤中实现阳性结果和低并发症率。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号