首页> 外文期刊>Journal of Veterinary Internal Medicine >Evaluation of the Freestyle Optium Neo H point‐of‐care device for measuring blood glucose concentrations in sick calves
【24h】

Evaluation of the Freestyle Optium Neo H point‐of‐care device for measuring blood glucose concentrations in sick calves

机译:用于测量病人血液葡萄糖浓度的自由式优化Neo H护理装置的评估

获取原文
           

摘要

Background Data on the performance of a glucometer in calves with different diseases are currently lacking. Objective The primary objective of this study was to evaluate the reliability of a point of care glucometer in calves affected by different diseases relative to a traditional bench‐top autoanalyzer. Animals One hundred ninety‐six calves with different disorders in a referral hospital. Methods Prospective study. Venous blood samples were used for the determination of glucose concentrations in blood and plasma using the Freestyle Optium Neo H and autoanalyzer, respectively. Data were subjected to Passing‐Bablok regression and Bland‐Altman plots. The Freestyle Optium Neo H was the test method and the autoanalyzer was the reference method. The diagnostic performance of the glucometer relative to the autoanalyzer was assessed using 3 different plasma glucose concentrations. Results The Passing‐Bablok regression for the glucometer against the reference method revealed the presence of both proportional bias (1.12; 95% confidence interval [CI], 1.07‐1.18) and constant bias (?11.25; 95% CI, ?16.0 to ?7.70). The glucometer yielded 92.2%‐100% sensitivity and 86.4%‐96% specificity for the assessing glucose concentration based on different concentration thresholds. Conclusions and Clinical Importance The Freestyle Optium Neo H showed proportional and constant biases relative to the reference method. The glucometer showed poor performance according to criteria recommended by the International Standards Organization and the American Society for Veterinary Clinical Pathology. However, the glucometer determined hypoglycemia with high sensitivity and specificity therefore it might be used to diagnose hypoglycemia in calves with different diseases until calf‐specific POC glucometers are developed.
机译:目前缺乏关于牛犊血液仪在牛犊中的性能的背景数据。目的本研究的主要目标是评估受传统台式自动分析仪受不同疾病影响的小腿护理血糖点的可靠性。动物在推荐医院中有一百九十六个小牛,不同疾病。方法预期研究。静脉血液样品分别用于使用自由式Neo H和AutoAnalyzer测定血液和等离子体中的葡萄糖浓度。数据受到通过 - Bablok回归和Bland-Altman图。 Freestyle Optium Neo H是测试方法,AutoAnalyzer是参考方法。使用3种不同的等离子体葡萄糖浓度评估血液仪相对于自动分析仪的诊断性能。结果对参考方法对血糖仪的通过--BBABROK回归揭示了两种比例偏压(1.12; 95%置信区间[CI],1.07-1.18)和恒定偏差(?11.25; 95%CI,?16.0至? 7.70)。血糖仪的敏感性92.2%-100%-100%和86.4%-96%的特异性,用于评估葡萄糖浓度基于不同的浓度阈值。结论和临床重要性自由式优化Neo H显示相对于参考方法的比例和恒定偏差。血液仪根据国际标准组织和美国兽医临床病理学的标准表现出差的性能。然而,血糖仪确定具有高敏感性和特异性的低血糖,因此它可能用于诊断具有不同疾病的小腿中的低血糖直至产生小牛特异性PoC血糖仪。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号