摘要

The present paper deals with the leaching characteristics of coal combustion residues from chandrapura thermal power station, Jharkhand, India. The study was made under the laboratory as well as the field condition. From the laboratory study conducted so far it is hereby concluded that the leachates of coal combustion residues from chandrapura thermal power station with respect to potentiometric and trace elements analysis are within the permissible limits as per Indian Standards (IS:2490). From the study it is also found that the elements such as arsenic, boron, nickel,etc. could not be detected. The discharge point leachate also does not pose any environmental problem from the point of view of leaching of trace and/or toxic elements as per IS: 2490.