Significance of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Portal Vein System of Pancreatic Cancer Patients

机译:低keV下双源双能CT数据重建的先进图像的虚拟单能重建的意义增加了胰腺癌患者门静脉系统的图像质量

获取原文
           

摘要

Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving image quality for portal vein system of pancreatic cancer patients. Materials and methods: 47 patients with clinically suspected pancreatic cancer (all confirmed by pathology) were collected. Routine plain scan was performed with Siemens Force dual-source dual-energy CT followed by 3 scans respectively carried out in arterial phase, portal phase and delayed phase. Traditional virtual monoenergetic reconstructions (Mono_E) and new generation of virtual monoenergetic reconstructions (Mono+) were respectively performed on portal vein images to obtain virtual single energy images including Mono_ E70 keV, Mono_E 55 keV and Mono+ 70 keV and Mono+ 55 keV. The signal-to-noise ratio (SNR) and noise of portal vein, normal pancreatic tissues and pancreatic lesions of 100 kV, Mono_E and Mono+ images were compared. In addition, the contrast noise ratio of portal vein and lesions as well as pancreatic tissues and lesions (CNR PV, CNRtumor) were also compared. At the same time, two imaging physicians with rich clinical experiences read the films and scored the images of each group by using the 5-point scoring method. Results: Mono+ 55 keV images including SNRpv, SNRpanc , SNRtu mor, Noise, CNRpv, CNRtumor were statistically different from 100 KV images and Mono_E images (P < 0.05). As for the subjective score, Mono+ 55 keV i mage score also had the highest score, which had statistical significance (P < 0.05). The results showed that Mono+ 55 keV images had the best quality. Conclusion: The new generation of virtual Mono+ post-treatment can reduce image noise. Low energy Mono+ images can improve the contrast between pancreatic cancer lesions and portal of pancreatic cancer patients.
机译:目的:探讨双源计算断层扫描(DECT)虚拟单能重建技术在提高胰腺癌患者门静脉系统的图像质量方面的重要性。 材料和方法:收集47例临床疑似胰腺癌(通过病理学证实)。使用西门子力量的双源双能量CT进行常规纯扫描,然后分别在动脉阶段,门前相位和延迟相中进行3个扫描。传统的虚拟单体重建(MONO_E)和新一代虚拟单一体重建(MONO +)在门静脉图像上进行,以获得包括MONO_ E70KEV,MONO_E 55 KEV和MONO + 70 KEV和MONO + 55 KEV的虚拟单能图像。比较了100kV,单声道和单+图像的门静脉,正常的胰腺组织和胰腺病变的信噪比(SNR)和噪声。此外,还比较了门静脉和病变的对比度和病变以及胰腺组织和病变(CNR PV,CNRTUMOR)。与此同时,两位成像医师具有丰富的临床经验,通过使用5点评分方法读取电影并通过5点评分方法对每个组的图像进行评分。 结果:Mono + 55 kev图像,包括SNRPV,SNRPanc,SNRTU MOR,噪声,CNRPV,CNRTumor与100 kV图像和MONO_E图像有统计不同(P <0.05)。至于主观评分,Mono + 55 kev I法师分数也具有统计学意义的最高分(P <0.05)。结果表明,Mono + 55 kev图像具有最佳质量。 结论:新一代虚拟单声道+后处理可以降低图像噪声。低能量单声道+图像可以改善胰腺癌病变与胰腺癌患者的门户之间的对比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号