Background and Aims: We devised a guard which can be slid and fixed over the central venous puncture needle at a desired length (measured through ultrasound) preventing the needle from penetrating deeper into the skin beyond this guard. This randomized, single blinded, controlled study was designed to evaluate the success of ultrasound guided internal jugular vein (IJV) cannulation using measured guided needle with guard in terms of success and occurrence of complications. Material and Methods: After ethical approval and written informed consent from the patients ultrasound-guided right-sided IJV cannulation was done with a conventional puncture needle (length of 6.4 cm) in the control group (n = 210) and with a conventional puncture needle with a guard fixed proximal to the bevel at a distance equal to the distance between the skin entry point and the midpoint of IJV measured with the help of USG in the study group (n = 210). The primary outcome studied was the number of attempts for successful cannulation. The secondary outcomes studied were complications and ease of cannulation. Results: 419 patients were randomized into control (n = 209) and study groups (210). Successful IJV cannulation in the first attempt (primary endpoint) in the study group was significantly higher compared to the control group (98.6 vs. 85.7%, P = 0.007). Posterior venous wall puncture was reduced in the study group, that is, 0.5% (1/210) compared to control group, that is, 8.61% (18/209) (P = 0.001). Common carotid artery puncture was 7.18% (15/209) in control group and 0% (0/210) in study group (P = 0.001). Operators rated better ease in study group (P 0.001). Conclusions: The use of measured guided needle with guard significantly improved the accuracy, success and ease of USG guided IJV cannulation and decreased complications.
机译:背景和宗旨:我们设计了一个可以滑动并以所需的长度(通过超声测量)在中央静脉穿刺针上固定,防止针深入穿透到这种卫兵之外的皮肤上。这种随机的单一盲目的受控研究旨在评估超声引导的内部颈静脉(IJV)插管的成功,使用测量针在成功和发生并发症的成败方面具有防护装置。材料和方法:在对照组(N = 210)中的常规穿刺针(n = 210)和传统穿刺针和常规穿刺针和常规穿刺针和常规穿刺针进行了伦理批准和书面知情同意。通过在等于皮肤入口点与IJV之间的距离的距离处固定到斜面的斜面,在研究组中的USG的帮助下测量(n = 210)。研究的主要结果是成功插管的尝试次数。研究的二次结果是并发症和插管的缓解。结果:419名患者被随机转化为对照(n = 209)和研究组(210)。与对照组相比,研究组的第一次尝试(主要终点)中的成功IJV插管(98.6 vs.85.7%,P = 0.007)显着高得多。研究组后静脉壁穿刺降低,即与对照组相比,0.5%(1/210),即8.61%(18/209)(p = 0.001)。对照组的常见颈动脉穿刺为7.18%(15/209),研究组中0%(0/210)(p = 0.001)。操作员在研究组中更好地估值(P <0.001)。结论:使用测量的引导针与防护装置显着提高了USG引导IJV插管的准确性,成功和易于缓解和减少的并发症。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号