Practical Experiences with the First Relative Gravimeter of Type Scintrex CG-6 Autograv in Dubai, The United Arab of Emirates

机译:迪拜迪拜迪拜迪拜赛型赛车CG-6 Autograv的第一个相对重子的实践经验

获取原文
       

摘要

In September 2019, the Dubai Municipality of Dubai Emirate, the United Arab of Emirates, has received its first Scintrex CG-6 Autograv gravity meter. This paper describes the installation and initial gravity signals with the new CG-6 Autograv gravimeter. Two gravity field sites have been selected in Dubai City and Hatta mountainous area. The relative gravity field measurements have been recorded for about one month time span; two weeks in Dubai and two weeks in Hatta. Among different effects reducing the gravity measurements, the tide and drift corrections have been focused on this paper. Two tidal models have been applied to reduce the tide effect based on the automated ETGTAB of the CG-6 gravimeter and ETERNA3.3 software. The results regarding the tide correction show very small discrepancies between both models (ETGTAB and ETERNA3.3) of about 2.2 μGal and 2.6 μGal in terms of standard deviations at Dubai and Hatta gravity stations, respectively. So, the outcome of the precise tidal model of CG-6 Autograv gravimeter is reliable for tidal reduction within Dubai area and its surroundings. Regarding the drift correction, the CG-6 Autograv provides low instrument drift values about 2.44 μGal and - 2.35 μGal per day for the Dubai and Hatta stations, respectively. Furthermore, it is recommended that the Hatta gravity station would be considered as a stable and trusted gravity site. For Dubai gravity station, the gravity observations are affected by some noise s from traffic activities while recording the gravity signal during the working days. Therefore, it is recommended for Dubai gravity station to be measured during the weekends and at nights in order to avoid any noises affecting the CG-6 gravimeter.
机译:2019年9月,迪拜迪拜酋长国市迪拜市民于阿联酋酋长国,已收到其第一个Scintrex CG-6 Autograv Gravity Meter。本文介绍了具有新型CG-6 AutoGrav重量计的安装和初始重力信号。迪拜市和哈塔山区选出了两座重力场网站。已经记录了相对重力场测量约一个月的时间跨度;迪拜两周,哈塔两周。在降低重力测量的不同效果中,潮汐和漂移校正已经集中在本文上。已经应用了两个潮汐模型,以减少基于CG-6重胎计和ETERNA3.3软件的自动etgtab的潮汐效应。关于潮汐校正的结果分别在迪拜和哈塔重力站的标准偏差方面显示了约2.2μga​​l和2.6μgal的模型(Etgtab和Eterna3.3)之间的非常小的差异。因此,CG-6 Autograv仪的精确潮汐模型的结果可靠,在迪拜地区及其周围环境内的潮汐减少是可靠的。关于漂移校正,CG-6 AutoGrav分别为迪拜和哈塔站提供约2.44μgAl和-2.35μgal的低仪器漂移值。此外,建议将哈塔重力站视为稳定且可信赖的重力站点。对于迪拜重力站,重力观测受到来自交通活动的一些噪声的影响,同时在工作日内记录重力信号。因此,建议在周末和夜间测量迪拜重力站,以避免任何影响CG-6重胎计的噪音。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号