首页> 外文期刊>World Allergy Organization Journal >Fine-tuning the use of a skin prick test device
【24h】

Fine-tuning the use of a skin prick test device

机译:微调使用皮肤刺测试装置

获取原文
获取外文期刊封面目录资料

摘要

Background Skin prick tests (SPTs) are the gold standard for the diagnosis of IgE-mediated allergic diseases. Newly introduced devices have different results in performance. This study aimed to provide data for sensitivity, reproducibility, and acceptability of a new SPT device by using different techniques. Methods The study was conducted in 4 sections. Different application techniques were evaluated. In the first section, a drop of histamine/saline was put by vial (V). In the second section, it was taken from a well via the test device (W). ALK? Lancet served as a reference in both sections. The techniques were as follows; 1) apply vertical pressure (VP/WP), 2) apply vertical pressure and rotate 90° clockwise (VC/WC), 3) apply vertical pressure and rotate 90° clockwise and then counter-clockwise (VCC/WCC). Pain assessment was performed by using the Wong-Baker FACES Pain Rating Scale. Different histamine concentrations were transferred from the well by the Oryum device and applied as WC in section 3. Lancet and Oryum-WP were compared in terms of time and allergen adequacy in section 4. Results In the first section the sensitivity of all techniques for Oryum and lancet were 100%. The false positivity of Oryum-VP, WP and lancet were found 0%. The Oryum-VP technique was found the best for intrapatient coefficient of variation (CV) (10.72%) (p??0.001). The interpatient CV was similar in the Oryum-VP, VC, VCC and lancet techniques and was different from the Oryum-WP (p??0.001). In the second section, all Oryum techniques yielded high sensitivities (100%). False-positive results were obtained more in Oryum-WC and WCC. Oryum-WP technique had the lowest pain score. In the 3rd section, the high positive correlation between histamine concentrations was observed (r?=?0.731). In terms of time and allergen adequacy, Oryum-WP was superior to the lancet. Conclusion Oryum-VP and WP techniques are reliable, tolerable and comparable with the lancet technique.
机译:背景技术皮肤刺测试(SPT)是诊断IgE介导的过敏性疾病的金标准。新引入的设备具有不同的性能结果。本研究旨在通过使用不同的技术提供新SPT设备的灵敏度,再现性和可接受性的数据。方法在4个部分进行。评估了不同的应用技术。在第一部分中,通过小瓶(V)放入一滴组胺/盐水。在第二部分中,通过测试装置(W)从井中取出。 ALK?柳叶刀作为两段的参考。技术如下; 1)施加垂直压力(VP / WP),2)施加垂直压力并旋转90°顺时针(VC / WC),3)施加垂直压力并顺时针旋转90°,然后逆时针(VCC / WCC)旋转。通过使用Wong-Baker面临疼痛评定量表进行疼痛评估。由Oyum器件从孔中转移不同的组胺浓度,并在第3节中施加WC。在第4节中的时间和过敏原于过敏原的情况下比较刺血针和ORYUM-WP。结果是第一部分OYUM所有技术的敏感性和柳叶酱均为100%。发现Oryum-VP,WP和柳叶醛的假阳性0%。 ORYUM-VP技术被认为是对窝内部变异系数(CV)的最佳(10.72%)(P?<→0.001)。扰动性CV在奥比尤-VP,VC,VCC和刺血针技术中类似,与OYUM-WP(P?<0.001)不同。在第二部分中,所有ORYUM技术都产生高敏感性(100%)。在Oryum-WC和WCC中获得假阳性结果。 ORYUM-WP技术具有最低的疼痛评分。在第3段中,观察到组胺浓度之间的高正相关(R?= 0.731)。在时间和过敏原的充足性方面,Oryum-WP优于刺血针。结论ORYUM-VP和WP技术可靠,可容忍和与柳叶刀技术相媲美。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号