IntroductionAccurate, precise and reliable laboratory test results play a critical role in medical decision making. To satisfy the increasing needs in clinical laboratory tests, the analyzers have been advanced. In this study, authors aimed to evaluate the analytical performance of the Alinity i system (Abbott Laboratories, IL, USA) for diverse analytes measured by using immunoassay principle.Materials and methodsAnalytical performance of recently launched Alinity i system has been evaluated for 31 assays in aspects of precision, linearity and analytical measurement range, correlation with the Architect i2000sr system (Abbott Laboratories), carry-over, and reference interval validation in accordance with CLSI guidelines.ResultsThe within-laboratory CVs of the analytes tested in the study ranged between 1.00 and 7.84%, which met vendor claimed value in precision. In linearity test, most assays satisfied acceptable linearity criteria, best-fit first order regression or polynomial regression with nonlinearity smaller than ±10%, compared with linear regression. The recovery of each analyte distributed from 90.1 to 109.7%. The coefficient of determination (R2) for each test was larger than 0.95 except for folate when compared to the results obtained from existing routine analyzer and statistically or clinically equivalent. The carry-over rates were acceptable, and reference intervals were validated.ConclusionThrough this study, acceptable analytical performance of novel Alinity i system has been verified. It is expected to readily replace existing instrument and to be an option for laboratories considering introduction of automated immunoassay analyzer.
机译:引入简介,精确可靠的实验室测试结果在医学决策中发挥着关键作用。为了满足临床实验室测试中不断增加的需求,分析仪已经进入。在这项研究中,作者旨在评估通过使用免疫测定原理测量的ALINITY I系统(Abbott Laboratory,IL,USA)的分析性能。最近发射的ALINITY I系统的材料和方法分析了31个测定精度,线性度和分析测量范围的各个方面,与架构师I2000SR系统(Abbott Laboratories),随续和参考区间验证的相关性,以及在研究中测试的分析物的实验室内CV的结果范围为1.00 7.84%,达到了精确度的供应商声称的价值。在线性试验中,与线性回归相比,大多数测定满足可接受的线性标准,最适合的第一订单回归或多项式的非线性,非线性小于±10%。分析物的回收率从90.1分布在90.1至109.7%。与从现有常规分析仪获得的结果相比,每次测试的测定系数(R2)大于0.95,除了从现有常规分析仪获得的结果和统计上或临床上等同。随机率是可接受的,并且验证了参考间隔。结论该研究,已验证了新型ALINITY I系统的可接受的分析性能。预计考虑到介绍自动免疫测定分析仪,预计将容易替换现有仪器并成为实验室的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号