首页> 外文期刊>ScientificWorldJournal >An Autopsy of Nanofiltration Membrane Used for Landfill Leachate Treatment
【24h】

An Autopsy of Nanofiltration Membrane Used for Landfill Leachate Treatment

机译:用于垃圾渗滤液处理的纳滤膜的尸体

获取原文
           

摘要

Komurcuoda leachate treatment plant, Istanbul, which consists of membrane bioreactor (MBR) and nanofiltration (NF) system, faced rapid flux decline in membranes after 3-year successful operation. To compensate rapid flux decline in membranes, the fouled membranes were renewed but replacement of the membranes did not solve the problem. To find the reasons and make a comprehensive analysis, membrane autopsy was performed. Visual and physical inspection of the modules and some instrumental analysis were conducted for membrane autopsy. Membranes were found severely fouled with organic and inorganic foulants. Main foulant was iron which was deposited on surface. The main reason was found to be the changing of aerator type of MBR. When surface aerators were exchanged with bottom diffusers which led to increasing of dissolved oxygen (DO) level of the basin, iron particles were oxidized and they converted into particulate insoluble form. It was thought that probably this insoluble form of the iron particles was the main cause of decreased membrane performance. After the diagnosis, a new pretreatment alternative including a new iron antiscalant was suggested and system performance has been recovered.
机译:Komurcuoda渗滤液处理厂,伊斯坦布尔,由膜生物反应器(MBR)和纳米滤灰(NF)系统组成,3年成功运行后膜的快速助焊剂下降。为了补偿膜的快速通量下降,核糖膜被更新,但替代膜没有解决问题。为了找到原因并进行全面的分析,进行了膜尸检。对模块的视觉和物理检查和一些仪器分析进行膜尸检。发现膜严重归结为有机和无机污垢。主要污垢是沉积在表面上的熨斗。发现主要原因是曝气机型MBR的变化。当用底部扩散器交换表面曝气器时导致盆地的溶解氧(DO)水平的增加,铁颗粒被氧化,并将它们转化为颗粒不溶性形式。认为可能是这种不溶性形式的铁颗粒是膜性能下降的主要原因。在诊断后,建议新的预处理替代品,并提出了一种新的铁防担剂,并恢复了系统性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号