Differences of Various Region-of-Interest Methods for Measuring Dopamine Transporter Availability UsingTc99m-TRODAT-1 SPECT

机译:使用用于测量多巴胺转运仪可用性的各种兴趣区域的差异使用的是使用它的速度 - TODAT-1 SPECT

获取原文
   

获取外文期刊封面封底 >>

       

摘要

This study was to investigate whether various region-of-interest (ROI) methods for measuring dopamine transporter (DAT) availabilities by single photon emission computed tomography (SPECT) are statistically different, whether results of medical research are thereby influenced, and causes of these differences. Eighty-four healthy adults withTc99m-TRODAT-1 SPECT and magnetic resonance imaging (MRI) scans were included. Six major analysis approaches were compared: (1) ROI drawn on the coregistered MRI; (2) ROIs drawn on the SPECT images; (3) standard ROI templates; (4) threshold-ROIs; (5) atlas-based mappings with coregistered MRI; and (6) atlas-based mappings with SPECT images. Using the atlas-based approaches we assessed the influence of striatum ROIs by slice-wise and voxel-wise comparisons. In (5) and (6), three partial-volume correction (PVC) methods were also explored. The results showed that DAT availabilities obtained from different methods were closely related but quite different and leaded to significant differences in determining the declines of DAT availability per decade (range: 5.95–11.99%). Use of 3D whole-striatum or more transverse slices could avoid biases in measuring the striatal DAT declines per decade. Atlas-based methods with PVC may be the preferable methods for medical research.
机译:该研究是通过单光子发射计算断层扫描(SPECT)来研究用于测量多巴胺转运蛋白(DAT)可用性的各种兴趣区域(ROI)方法是否有统计学不同,从而影响医学研究的结果,以及这些结果差异。包括八十四名健康成年人,其中包括跨国公司 - TODAT-1 SPECT和磁共振成像(MRI)扫描。比较六种主要分析方法:(1)在重铸MRI上绘制的ROI; (2)在SPECT图像上绘制的ROI; (3)标准ROI模板; (4)阈值 - ROI; (5)基于地图集的映射,具有内心的MRI; (6)与SPECT图像的基于阿特拉斯的映射。使用基于地图集的方法,我们通过切片 - 明智的和voxel-明智的比较评估了纹状体rois的影响。在(5)和(6)中,还探讨了三种部分体积校正(PVC)方法。结果表明,从不同方法获得的DAT可用性密切相关但相当不同,并导致确定每十年可用性下降的显着差异(范围:5.95-11.99%)。使用3D全纹状或更多横向切片可以避免偏差测量每十年下降的偏向。具有PVC的基于地图的方法可以是医学研究的优选方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号