首页> 外文期刊>Revista IBRACON de Estruturas e Materiais >Global stability of buildings’ structural systems considering beam-wall connections
【24h】

Global stability of buildings’ structural systems considering beam-wall connections

机译:考虑梁墙连接的建筑物结构系统的全球稳定性

获取原文
           

摘要

Several factors influence the stability of concrete structures, such as building height, structural components’ rigidity, bracing system, beam-wall connection rigidity, among others. Global structural stability is evaluated according to NBR 6118/2014 by the α e γ z parameters. This article aims to evaluate the global structural stability concrete structures considering the eccentricity of the beam-wall connections. With the aid of software Abaqus? and TQS?, reticulated models were analyzed to evaluate the contribution of the eccentricity of the beam-wall connections on the global stability and the rigidity of the connections. The geometric nonlinear effects were disregarded in these analyses. The stability parameters from NBR6118/2014 were evaluated in the frame models, as well as the flexibilization criteria from the TQS? software, LEPMOL e REDMOL. The results of the displacement analysis show an increase of 26.45%, comparing the centered connection to the more eccentric connection.
机译:有几个因素影响混凝土结构的稳定性,如建筑物高度,结构部件的刚性,支撑系统,梁壁连接刚度等。通过αEγZ参数根据NBR 6118/2014评估全局结构稳定性。本文旨在评估考虑梁壁连接的偏心的全球结构稳定性混凝土结构。借助软件Abaqus?分析了TQS?,网状模型来评估梁壁连接偏心率对连接的全局稳定性和刚性的贡献。在这些分析中忽略了几何非线性效应。来自框架模型中的NBR6118 / 2014的稳定性参数,以及来自TQ的Flexibilization标准?软件,Lepmol E Redmol。位移分析的结果显示增加26.45%,比较了与更偏心的连接的中心连接。